AGXCEL INTEGRATION INTO THE TRIMBLE
(Read Instructions Completely before Beginning Installation)
WWW.AGXCEL.COM
877-218-1981
Advance PWM Tab
1. Press the Advance PWM tab On the Field-IQ Drive Calibration. Set the settings as shown:
Base PWM Frequency ............ 100
Dither Frequency .......................
0
Dither Amplitude .......................
0
Dither Control:............... Absolute
Flow Calibration
2.
Select
Field-IQ – Calibrate
on the
Calibration screen. This brings up the
screen where you can select
Flow Cali-
bration
.
3. The
Flow Calibration
numbers may
have already been set in the
Drive Setup
. You can verify or
update the settings here.
4.
After pressing
“Run Calibration”
,
a screen that will allow you to in-
put your
Target Rate and Spee
d.
Enter your typical application rate
and field speed. During calibration, the system will run at the correct flow for this
rate speed.
5. You will need a
stop watch
to measure time. AgXcel recommends running the test
for some duration in minutes for simple math. When your containers are in position
under multiple fertilizer outlets, press the Start Flow, then turn
on the Field IQ master switch and start your timer. The system
will begin to run. When your containers are near full, push Stop
Flow.
6.
Now you will need to measure the amount of liquid caught.
The number you enter must be in gallons per minute per row.
•
Find total amount caught in ounces.
•
Divide total ounces by number of rows caught.
•
Divide ounces / row by 128 to convert to gallons /
row
7. After entering the amount caught, the Flow Calibration
number will automatically change. If it has changed more
than 5%, review your catch test and repeat.
NOTE:
AgXcel recommends running this procedure to verify set
up is completed correctly. We recommend changing the flow
calibration back to the standard ion flow meter calibration
shown on the flow calibration on page 6.