Wiring the KM45 Series Submersible Tank
Monitor sensor
Wiring the AgSense KM45 Tank Monitor sensor: You can have up to 2 Tank Monitor sensors
wired into this unit. Starting with sensor 1, find the group of terminals (3) with the group label 1.
1.
Connect the White wire from the Tank Monitor sensor to the terminal marked PWR
as shown above.
2.
Connect the Brown wire from the Tank Monitor sensor to the terminal marked GND
as shown above.
3.
Connect the Yellow wire from the Tank Monitor sensor to the terminal marked SIG
as shown above.
Notes: Green wire not used - Repeat steps 1-3 for second Tank Monitor sensor at group 2.
DO NOT shorten or lengthen the submersible sensor cable!! This cable includes a vent tube and
filter that are required for proper sensor operation, DO NOT MODIFY!
Note: You must make sure the jumpers are set correctly for each sensor installed
before turning power on to this unit – see Page 14 for jumper setting information.
Page 26