background image

 

 
 
 
 
 
 
 

 
 

 
 
 
 
 

2015-18 Aqua Trac Pro 

Wiring Manual 

 

 

Revised January 1, 2018 

 
 
 
 
 
 
 
 
 
 

 

 
 

Summary of Contents for Aqua Trac Pro

Page 1: ...2015 18 Aqua Trac Pro Wiring Manual Revised January 1 2018...

Page 2: ...g the EnviroPro Probe Page 12 Connecting the Greenshield Probe Page 13 Connecting the Waterscout SM100 Sensor Page 14 Connecting the AgSense Rain Bucket Page 15 Connecting the AgSense Temperature Sens...

Page 3: ...act your AgSense Dealer to finish setup and configuration of this unit to read the sensors that you have installed Note 2 The pins marked SENSOR POWER as shown above should have a jumper connecting th...

Page 4: ...olar panel Find the group of terminals 2 with the group label PWR 1 Connect the Black Wire from the solar panel to the terminal marked GND as shown above 2 Connect the White or Red Wire from the solar...

Page 5: ...of terminals 3 with the group label WM 1 1 Connect the Red wire from the Watermark sensor to the terminal marked PWR as shown above 2 Connect the Black wire from the Watermark sensor to the terminal m...

Page 6: ...wire from the Decagon 10HS GS1 sensor to the terminal marked PWR as shown above 2 Connect the Bare wire from the Decagon 10HS GS1 sensor to the terminal marked GND as shown above 3 Connect the Red wi...

Page 7: ...f terminals 3 with the group label SDI 1 Connect the Blue wire from the AquaCheck probe to the terminal marked SIG as shown 2 Connect the Yellow Green stripe wire from the AquaCheck probe to the termi...

Page 8: ...the Blue wire from the Sentek probe to the terminal marked SIG as shown above 2 Connect the Yellow wire from the Sentek probe to the terminal marked GND as shown above 3 Connect the Red wire from the...

Page 9: ...e group of terminals 3 with the group label SDI 1 Connect the Red wire from the Decagon Sensor to the terminal marked SIG as shown above 2 Connect the Bare wire from the Decagon Sensor to the terminal...

Page 10: ...nals 3 with the group label SDI 1 Connect the White wire from the Sentek probe to the terminal marked SIG as shown above 2 Connect the Green wire from the Sentek probe to the terminal marked GND as sh...

Page 11: ...abel SDI 1 Connect the Green wire from the CS Sensor to the terminal marked SIG as shown above 2 Connect the Clear Black and Orange wires from the CS Sensor to the terminal marked GND as shown above a...

Page 12: ...s 3 with the group label SDI 1 Connect the Blue wire from the Sensor to the terminal marked SIG as shown above 2 Connect the White wire from the Sensor to the terminal marked GND as shown above 3 Conn...

Page 13: ...nals 3 with the group label SDI 1 Connect the Blue wire from the Sensor to the terminal marked SIG as shown above 2 Connect the Black wire from the Sensor to the terminal marked GND as shown above 3 C...

Page 14: ...als 3 with the group label SDI 1 Connect the Green wire from the Sensor to the terminal marked SIG as shown above 2 Connect the Yellow wire from the Sensor to the terminal marked GND as shown above 3...

Page 15: ...the Sensor to the terminal marked SIG as shown above 2 Connect the Black wire from the Sensor to the terminal marked GND as shown above 3 Connect the White wire from the Sensor to the terminal marked...

Page 16: ...se Rain Bucket Find the group of terminals 2 with the group label RAIN 1 Connect the Green wire from the AgSense Rain Bucket to the terminal marked GND as shown above 2 Connect the Red wire from the A...

Page 17: ...Sense Temp Sensor Find the group of terminals 2 with the group label TEMP 1 Connect the Green wire from the AgSense Temp sensor to the terminal marked GND as shown above 2 Connect the Brown wire from...

Page 18: ...moisture value just to the right Some Sentek sensors will also have an additional column displaying salinity Below the sensor readings is a display of the soil type in the general area where the prob...

Page 19: ...sensors Page 13 Watermark 200TS Temperature Sensor Page 14 Tank Monitoring Liquid Level Sensor Also included in this section is a new overview picture of the unit Page 10 showing slight changes to the...

Page 20: ...our AgSense Dealer to finish setup and configuration of this unit to read the sensors that you have installed Note 2 The pins marked SENSOR POWER as shown above should have a jumper connecting the mid...

Page 21: ...Jumper Settings Note you cannot mix ETape Watermark Decagon 10HS GS1 5v sensors and 12v Tank Monitor Acclima TDR Sensors only 1 type may be used at a time Page 19...

Page 22: ...p label 1 1 Connect one Green wire from the Watermark sensor to the terminal marked GND as shown above 2 Connect the other Green wire from the Watermark sensor to the terminal marked SIG as shown abov...

Page 23: ...termark Temp Sensor 200TS Find the group of terminals 2 with the group label TEMP 1 Connect one Red wire from the 200TS Temp sensor to the terminal marked GND as shown above 2 Connect the second Red w...

Page 24: ...marked PWR as shown above 2 Connect the Red wire from the ETape Sensor to the terminal marked GND as shown above 3 Connect the White wire from the ETape Sensor to the terminal marked SIG as shown abo...

Page 25: ...to the terminal marked PWR as shown above 2 Connect the Black wire from the Tank Monitor sensor to the terminal marked GND as shown above 3 Connect the White wire from the Tank Monitor sensor to the...

Page 26: ...as shown above 5 Connect the Black wire from the Pressure Transducer to the terminal marked GND as shown above 6 Connect the White wire from the Pressure Transducer to the terminal marked SIG as shown...

Page 27: ...ON Closed Connection 1 Connect one wire from the Pressure Switch or Float Switch to the terminal marked PWR as shown above 2 Connect the second wire from the Pressure Switch or Float Switch to the te...

Page 28: ...ank Monitor sensor to the terminal marked GND as shown above 3 Connect the Yellow wire from the Tank Monitor sensor to the terminal marked SIG as shown above Notes Green wire not used Repeat steps 1 3...

Page 29: ...eing used in extremely explosive liquids fuels an explosion proof sensor is available contact your dealer to get information and pricing and availability of this sensor from AgSense How To Configure a...

Page 30: ...air on any unit that fails due to defect in materials or workmanship AgSense labor and parts would be provided free of charge during the warranty period This does not include dealer labor What is not...

Page 31: ...onsibility for the reliability of this technology Customer acknowledges that AgSense does not have the ability to control the reliability of GPS Satellite and Internet Technology AgSense specifically...

Page 32: ...AgSense LLC 259 Dakota Ave S PO Box 53 Huron SD 57350 605 352 8350 www AgSense net...