Case 1. Starting failure
CHECK
PROBABLE CAUSES
ACTION
fuel tank
∅
incorrect fuel
∅
drain it and use correct fuel
fuel filter
∅
fuel filter is clogged
∅
clean
carburetor adjustment screw
∅
out of normal range
∅
adjust to normal range
sparking (no spark)
∅
spark plug is fouled/wet
∅
clean/dry
∅
plug gap is incorrect
∅
correct (GAP: 0.6 to 0.7 mm)
spark plug
∅
disconnected
∅
retighten
Case 2. Engine starts but does not keep running/hard re-starting
CHECK
PROBABLE CAUSES
ACTION
fuel tank
∅
incorrect fuel or staled fuel
∅
drain it and use correct fuel
carburetor adjustment screw
∅
out of normal range
∅
adjust to normal range
muffler, cylinder (exhaust port)
∅
carbon is built-up
∅
wipe away
air cleaner
∅
clogged with dust
∅
wash
cylinder fin, fan cover
∅
clogged with dust
∅
clean