The two ends of the cable should have a termination resistor connected across the two wires.
Without termination resistors, reflections of fast driver edges can cause multiple data edges that
can cause data corruption. The value of each termination resistor should be equal to the cable
impedance (typically 120
Ω for twisted pairs).
The above drawing shows the RS485 schematic of the ASR650 including the fail-safe resistors
and protection diodes. The resistors are necessary for biasing the lines to known voltages and
nodes will not interpret the noise from undriven lines as actual data.
The RS485 baud rate can be configured from 9600 to 115200 baud. Please ensure that all nodes
use the same and correct setting.
It is very important that each device on the bus uses a different network- or
node address. If several readers are using the same address, data collision
might be the result. You can change the reader’s node addresses via the
ASR-PC-Demo
Software.