AGM Global Vision
18
2.2.5 TRIGGER CALIBRATION
Trigger Calibration performs the correction of nonuniformity of display in the
mode preset in the FFC menu.
1. Hold button to show the menu.
2. Rotate the wheel to select
menu item and press to trigger the
calibration.
3. Hold button to exit.
2.2.6 FFC (FLAT FIELD CORRECTION)
Flat Field Correction (FFC) function can correct nonuniformity of display.
1. Hold button to show the menu.
2. Rotate the wheel to select
menu item and press to switch the FFC
mode between Manual, Auto and External.
Manual:
Enter Trigger Calibration in the menu and press button to correct
the nonuniformity of display (refer to section 2.2.5).
Auto:
The riflescope performs FFC automatically when switching on or
rebooting the camera.
External:
Cover the lens cap, then enter Trigger Calibration in the menu and
press button to correct the nonuniformity of display (section 2.2.5).
3. Hold button to exit.
2.2.7 CVBS OUTPUT
You can view the video on CVBS monitor, to get a better and clear image, more
convenient to check the detail.
1. Connect the USB-CVBS cable to USB port of thermal riflescope and to
monitor’s CVBS port.
NOTE:
USB-CVBS cable need to be purchase separately.
NOTE:
CVBS Output function doesn’t support hot plug, so please connect the cable
before power on.
2. Hold button to show the menu.
3. Select
CVBS
menu item and press button to turn on or turn off the CVBS
video output.
2.2.8 PICTURE IN PICTURE MODE
1. Hold button to show the menu.
2. Select PIP menu item and enter Picture In Picture (PIP) mode. The
details show in the upper part of screen.
NOTE:
When Reticle is enabled, the PIP view is the detail of crosshair.
When Reticle is not enabled, the PIP view is the detail of central part.