2.2.4  MAIN MENU

NOTE

Enter the main menu with a long press of the joystick Up. Press the joystick Left/Right 

to select between the main menu options.

All menu is displayed in the central area of the image. The reason is the reduced field of 

view of the day sight by higher magnifications. Reaching a low battery state the device 

gives a warning in the top left corner of the central area. 

 

 EXIT

Press the joystick Up/Down to Exit, the Main Menu will not disappear 

automatically.

 

 MODE

Press the joystick Up/Down to change your thermal imager to Clip-On mode  

(C = Clip-On;  M = Monocular).

NOTE 

It is recommended to use up to 3x magnification of the primary optical unit in order to 

keep the menu and all submenus visible in clip-on mode.

 

 AUTO NUC

Press the joystick Up/Down to turn Automatic Non-uniformity Calibration On/

Off. In the automatic mode the need for calibration is based on software algo-

rithm, calibration starts automatically. When choose Off, user will do calibration 

manually by either lens cover(silent without shutter) or press middle button 

(with shutter). Manual calibration function is in Quick Menu.

Summary of Contents for ANACONDA-MICRO

Page 1: ...USER MANUAL ANACONDA MICRO THERMAL IMAGING CLIP ON SYSTEM...

Page 2: ...tions the International Economic Emergency Powers Act and various U S embargoes and sanctions AGM Global Vision products may not be exported re exported or transferred contrary to U S export control l...

Page 3: ...1 1 System Description 5 1 2 Main Features 5 1 3 Main Parts and Components 5 2 OPERATING INSTRUCTIONS 7 2 1 Installation and Mounting 7 2 2 Controls and Indication 11 2 3 Operating 16 3 WARRANTY INFO...

Page 4: ...example at sunset objects will have absorbed different levels of heat resulting in greater temperature differences and better contrast WARNING When left in storage for a longer period of time batterie...

Page 5: ...ncrease of operating time Onboard Wi Fi module for live video streaming and video images recording via application are also available 1 2 MAIN FEATURES Quick conversion of daytime optics into thermal...

Page 6: ...Bag 5 Wi Fi Antenna 15 Small Day Scope Adapter 42 50 mm Optional 6 Attachment Place 7 Extension Interface 16 Middle Day Scope Adapter 51 59 mm Optional 8 Battery Compartment Cover 9 USB and Video Con...

Page 7: ...use Clean all optical surfaces with a lens tissue 2 1 2 BATTERIES INSTALLATION Turn the battery cover knob clockwise until stop and remove the cover from battery compartment see the Figure 2 1 OPEN p...

Page 8: ...with the rail Tighten the fixation screw 2 1 4 INSTALLING THE CLIP ON ONTO THE LENS OF A DAY SCOPE Use the optional day scope adapter DSA to install the Anaconda Micro onto day scope lenses ATTENTION...

Page 9: ...rn the nut D CW CCW respectively for adapter s size adjustment 5 Affix the DSA to the day scope by locking the lever C Verify that the clip on is firmly secured to the day scope If necessary readjust...

Page 10: ...e Anaconda Micro Plug the other end of the cable to the external battery WARNING Do not disconnect the cable during data transfer 2 1 7 INSTALLATION OF THE INTERCHANGEABLE OCULAR OPTIONAL The intercha...

Page 11: ...selection Joystick Up Real time image Bring out Quick Menu Enter Main Menu Quick Menu Change parameters Main Menu Change parameters Joystick Down Real time image Bring out Quick Menu NA Quick Menu Cha...

Page 12: ...y If select of Zoom Palette Brightness Contrast Sharpness functions do not take place in 5 second the information disappear from display MANUAL SILENT CALIBRATION Use manual Non Uniformity Correction...

Page 13: ...he respective menu option The lower fixed bar under the object automatically appear on display Press the joystick Up Down to move the upper horizontal bar until the object fits entirely between the tw...

Page 14: ...u will not disappear automatically MODE Press the joystick Up Down to change your thermal imager to Clip On mode C Clip On M Monocular NOTE It is recommended to use up to 3x magnification of the prima...

Page 15: ...1 2 UNIT Press the joystick Up Down to select units of measurement Yards or Meters DEFECTIVE PIXEL REPAIR Press the joystick Up Down then close lens cover to repair defective pixel Defective pixels a...

Page 16: ...rter distance could recognize deviation and eliminate it by software correction The manufacturing process of the Anaconda Micro ensures the shooting preci sion tolerance within 3 to 7 cm at 100 m To a...

Page 17: ...he unit to a computer 1 Make sure the Wi Fi is activated as well Wait 10 seconds after turning the Wi Fi function on 2 Connect the Anaconda Micro to PC via USB interface refer to Section 2 1 5 3 Enter...

Page 18: ...too quickly always wait until image number disappears before taking next photo 3 Press the Video Camera icon on application main screen to record a video Always wait until video is saved before starti...

Page 19: ...with Anaconda Micro is on the Upside of previous point of impact previous aiming position change value Y Y press the joystick Down de crease Y value and vice versa While using the Alignment Correction...

Page 20: ...irt from the lenses 5 Dampen a cotton swab with ethanol and slowly gently wipe down the lenses Clean the glass surfaces using circular movements starting from the center of the lens and moving out tow...

Page 21: ...conjunction with equipment that is electrically or mechanically incompatible with or of inferior quality to the product as well as failure to maintain the environmental conditions specified by the ma...

Page 22: ...red with the correct postage AGM Global Vision will not be responsible for improper postage or merchandise that becomes lost or damaged dur ing shipment When sending product back please clearly write...

Page 23: ...Relief 24 mm Display OLED 1024x768 Video Recording Image Capturing Yes Storage 32 GB built in memory Wi Fi Built in Wi Fi module hotspot Data Transmission Live video streaming via Wi Fi APP Video ima...

Page 24: ...73 West Main Street PO Box 962 Springerville AZ 85938 USA Tel 1 928 333 4300 info agmglobalvision com www agmglobalvision com EUROPEAN OFFICE Andrey Lyapchev 7 Sofia P C 1756 Bulgaria Tel 44 292 255 0...

Reviews: