User’s and Service Guide
9
E8257D Option HAR
Service
Service
Troubleshooting
1. Before troubleshooting E8257D Option HAR, verify that the standard instrument is
operating properly with the Divider Mode Off. If not, troubleshoot in Standard Mode.
2. For the instrument to operate properly with the Option HAR circuitry installed (Divider
Mode On or Off), licenses are needed for the following options:
•
Option HAR
•
Option 1EH
3. If the Phase Noise in Divider Mode is does not meet specification (refer to
), replace the Divider Assembly.
4.
Measure the losses through Option HAR in Standard Mode (Divider Mode Off).
Figure 3
Divider Assembly with Connectors Labeled
Table 9
Divider Assembly
Assembly
Path
Frequency
Loss
Divider Assembly E8251-60433
P1 to P2
250 MHz to 3.2 GHz
≤
3 dB
Divider Assembly E8251-60433
P4 to P3
250 MHz to 3.2 GHz
≤
3 dB