![Agilent Technologies E2969A User Manual Download Page 42](http://html1.mh-extra.com/html/agilent-technologies/e2969a/e2969a_user-manual_2868646042.webp)
Appendix
Hardware Description
5-2 E2969-91020
Four-Digit Display
This four-digit numeric display indicates the states of the internal link
state machine.
The two digits on the left represent the downstream link of the test card
(only in case of AIC Test Mode), the link between the test card and the
add-in card plugged onto it.
The two digits on the right represent the upstream link of the test card,
this is the link between the test card and the target platform.
When all links have been established successfully during boot up, the
display shows “1010” for AIC Test Mode. Topology Test Mode displays a
“T10”. All other numbers indicate an error.
The following table shows the link states represented by the individual
numbers:
Number
in display
Link state
00
Detect.Quiet
01
Detect.Active
02
Polling.Active
03
Polling.Compliance
04
Polling.Configuration
05
Polling.Speed1
06
Polling.Speed2
07
Configuration.Linkwidth.Start
08
Configuration.Linkwidth.Accept
09
Configuration.Lanenum.Wait
Summary of Contents for E2969A
Page 1: ...Agilent E2969A Protocol Compliance Test Card for PCI Express User Manual AgilentT echnologies...
Page 4: ...Content 2 E2969 91020...
Page 32: ...Working with the PTC Administering the PTC 3 12 E2969 91020...
Page 38: ...Troubleshooting 4 6 E2969 91020 Check the Reportfile for errors all errors will be shown there...
Page 40: ...Troubleshooting 4 8 E2969 91020...
Page 50: ...Appendix Declaration of Conformity 5 10 E2969 91020 Declaration of Conformity...
Page 51: ...E2969 91020 6 1...