96 Agilent E1330B Digital I/O Module Command Reference
Chapter 5
SYSTem Subsystem
The
SYSTem
subsystem returns information about the module.
Syntax
SYSTem
:CDEScription? <number>
:CTYPe? <number>
:ERRor?
:VERsion?
:CDEScription?
SYSTem:CDEScription? <
number
>
returns the module description.
Parameters
Comments
•
This command is only available when using the downloaded SCPI driver.
•
<
number
>
is the instrument number. Because each Digital I/O module is a
single instrument,
<
number
>
is always 1.
•
The command returns the following string:
Quad 8-bit Digital I/O
:CTYPe?
SYSTem:CTYPe? <
number
>
returns the module number and manufacturer.
Parameters
Comments
•
This command is only available when using the downloaded SCPI driver.
•
The command returns the following string (revision number may vary and the
serial number is always set to 0):
HEWLETT-PACKARD,E1330B,0,A.05.00
Parameter Name
Parameter Type
Range of Values
Default
<
number
>
Numeric
1
None
Parameter Name
Parameter Type
Range of Values
Default
<
number
>
Numeric
0 to 99
None