![Agilent Technologies E1330B User'S Manual And Scpi Programming Manual Download Page 83](http://html.mh-extra.com/html/agilent-technologies/e1330b/e1330b_users-manual-and-scpi-programming-manual_2867439083.webp)
Agilent E1330B Digital I/O Module Command Reference
81
Chapter 5
DIGital:DATA
n
[:type]:HANDshake[:MODE]?
[SOURce:]DIGital:DATA
n
[:BYTE]:HANDshake[:MODE]?
returns a string
indicating the type of handshake set on the 8-bit port n.
[SOURce:]DIGital:DATA
n
:WORD:HANDshake[:MODE]?
returns a string
indicating the type of handshake set on the 16-bit port n.
[SOURce:]DIGital:DATA
n
:LWORd:HANDshake[:MODE]?
returns a string
indicating the type of handshake set on the 32-bit port n.
Parameters
Comments
•
The keyword
:LW32
may be used instead of
:LWORd
when using the
download version of the SCPI driver.
•
The handshake mode must be the same on all ports used in a multiple port
operation.
•
This command will return one of the following strings:
NONE
LEAD
TRA
PULS
PART
STR
•
:DATA
n
[:type]HANDshake?
is the sequence used for commands relating to
data handshaking at port n. The port number n must be the last character of the
keyword without spaces.
•
Related Commands:
[SOURce:]DIGital:CONTrol
n
:POLarity
,
[SOURce:]DIGital:CONTrol
n
[:VALue]
,
[SOURce:]DIGital:FLAG
n
:POLarity
,
[SOURce:]DIGital:HANDshake
n
:DELay
•
*RST Condition:
Mode is
NONE
on all ports.
Example
DIG:DATA3:HAND?
returns the handshake mode set on port 3.
Parameter Name
Parameter Type
Range of Values
Default
DATA
n
Numeric
BYTE
WORD
LWORd
none, 0, 1, 2, or 3
none, 0 or 2
none or 0
0
Summary of Contents for E1330B
Page 2: ......
Page 10: ...8 Notes ...
Page 11: ...9 Notes ...
Page 12: ...10 Notes ...
Page 32: ...30 Configuring the Agilent E1330B Digital I O Chapter 2 Notes ...
Page 42: ...40 Using the Agilent E1330B Digital I O Module Chapter 3 Notes ...
Page 58: ...56 Understanding the Agilent E1330B Digital I O Module Chapter 4 Notes ...
Page 104: ...102 Agilent E1330B Digital I O Module Command Reference Chapter 5 Notes ...