Transport & Shipping 

To package the instrument for shipping: 

Step Notes 

1. 

Place the instrument in its original packaging 

materials.

 

• 

If the original packaging materials are not available, 

use a professional packaging service. Contact your 
Agilent Service Center for more information.

 

2. 

Surround the instrument with at least 3 to 4 inches (8 

to 10 cm) of its original packing material or bubble-pack 
to prevent the instrument from moving in its shipping 
container.

 

 

3. 

After wrapping it with packing material, place the 

instrument in its original shipping container or a strong 
shipping container that is made of double-walled 
corrugated cardboard with 159 kg (350 lb) bursting 
strength. 

 

• 

The shipping container must be large and strong 

enough to accommodate your instrument and allow at 
least 3 to 4 inches (8 to 10 cm) on all sides for packing 
material.

 

4. 

Seal the shipping container securely with strong nylon 

adhesive tape.

 

 

5. 

Mark the shipping container “FRAGILE, HANDLE 

WITH CARE” to help ensure careful handling.

 

 

6. 

Use the address obtained from your Agilent 

Technologies Service Center.

 

 

7.  

Retain copies of all shipping papers.

 

 

CAUTION: 

Damage can result if the original packaging materials are not used. Packaging materials should be 

anti-static and cushion the instrument on all sides. NEVER USE STYRENE PELLETS IN ANY SHAPE AS 
PACKAGING MATERIALS. They do not adequately cushion the instrument or prevent it from moving in the 
shipping container. Styrene pellets can also cause equipment damage by generating static electricity or by lodging 
in fan motors.

 

1.12.

 

Maintenance 

The CC10X crates do not require any maintenance. There are no user serviceable parts inside. 

1.13.

 

Cleaning 

WARNING :

 Always power off the crate and disconnect the power cord before cleaning the crate. 

Cleaning procedures consist only of exterior cleaning. 

Clean the exterior surfaces of the crate with a dry lint-free cloth or a soft-bristle brush. If any dirt remains, wipe a 
cloth moistened in a mild soap solution. Remove any soap residue by wiping with a cloth moistened with clear water. 
Do not use abrasive compounds on any part of the crate. 

CAUTION :

 Avoid getting moisture inside the crate during exterior cleaning. Use just enough moisture to 

dampen the cloth. 

Do not wash the connector and switches. Cover these components while cleaning the crate. 

Do not use chemical cleaning agents, they may damage the crate. Avoid chemicals that contain 
benzene, toluene, xylene, acetone, or similar solvents. 

1.14.

 

Disposal and Recycling 

Electronic equipment should be properly disposed of. Acqiris crates must not be thrown out as normal waste. 
Separate collection is appropriate and may be required by law. 

User Manual: Agilent Acqiris 3-, 5-, and 8-slot cPCI Crates

 

                     

Page 8 of 28

 

Summary of Contents for ACQIRIS CC103

Page 1: ...cess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Dem...

Page 2: ...USER MANUAL AGILENT ACQIRIS 3 5 AND 8 SLOT CPCI CRATES...

Page 3: ...sumed for the use or the reliability of software firmware or any equipment that is not supplied by Agilent or its affiliated companies You can download the latest version of this manual from http www...

Page 4: ...6U modules 11 2 5 2 Installing 3U modules 11 2 5 3 Installing Filler Plug in 11 3 SPECIFICATIONS 12 3 1 Main Features 12 3 2 Power Supply 13 3 2 1 AC Input Specifications 13 3 2 2 DC Outputs Specifica...

Page 5: ...stalling the modules and operating the system 1 3 Organization of This Manual This manual is organized as follows Chapter 1 OUT OF THE BOX gives information you must know prior to using CC10X crates l...

Page 6: ...y an empty crate or handles need to be attached and two persons have to manipulate a loaded crate The smaller crates can be manipulated by one person WARNING If an instrument handle is damaged you sho...

Page 7: ...rack mount kits are available from Acqiris U1092A C31 XC103 RACK MOUNT ADAPTER for CC103 crate Height 3U 132 5mm U1092A C51 XC105 RACK MOUNT ADAPTER for CC105 crate Height 4U 177mm U1092A C81 XC108 R...

Page 8: ...in order to verify product performance All repairs replacement and spare parts are warranted for a period of 3 months Warranty extensions are available as an option In exercising this warranty Agilent...

Page 9: ...nt on all sides NEVER USE STYRENE PELLETS IN ANY SHAPE AS PACKAGING MATERIALS They do not adequately cushion the instrument or prevent it from moving in the shipping container Styrene pellets can also...

Page 10: ...WARNING Before connecting the crate to a power source read this chapter and the paragraph 1 5 Figure 2 1 Front view of the CC105 Figure 2 2 Rear view of the CC105 User Manual Agilent Acqiris 3 5 and...

Page 11: ...front panel and an other one on the rear panel of the CC10X For further information refer to the paragraph 3 6 3 Rack Mounting Dimensions and appendix 4 1 4 2 4 3 and 4 5 Specifications and Assembly I...

Page 12: ...ing the handles into place Tighten both front panel mounting screws to lock the module into place and insure proper grounding of the frame 2 5 2 Installing 3U modules CAUTION The XC100 6U to 3U Slot A...

Page 13: ...s flow air circulation Power supply and module slots are fully protected against over temperature Compact design for bench top and rack mount installation with the optional rack mount adapter The rack...

Page 14: ...thin the fuse holder on the rear panel All Fuses are Slow Blow 5x20mm CC103 T 4A H 250V CC105 T 6 3A H 250V CC108 low power T 6 3A H 250V CC108 and CC108 600 T 10A H 250V CC108 800 T 10A H 250 V for 1...

Page 15: ...W 12V 17A 204W 12V 17A 204W RMS Ripple 0 1 or 10mV whichever is greater 20MHz bandwidth Peak to Peak Noise 1 or 50mV whichever is greater 20MHz bandwidth Dynamic Response 2 or 100mV 25 load step Reco...

Page 16: ...ooling Capacity To be respected to ensure that the slot does not exceed the safe operating temperature CC103 3 slots 150W 50 C or 270 W 30 C CC105 5 slots 250W 50 C or 400 W 30 C CC108 8 slots 400W 50...

Page 17: ...slot connectors P1 and P2 3 3V P1 10 contacts 5V P1 8 contacts 12V P1 1 contact 12V P1 1 contact V I O P1 5 contacts P2 6 contacts GND P1 14 contacts P2 18 contacts Bus Frequency 66 MHz operation is...

Page 18: ...CK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 KEY AREA 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD...

Page 19: ...p 1 class A AS NZS CISPR 11 ICES NMB 001 This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme la norme NMB 001 du Canada Reference Standards Limit CISPR 11 2003 EN 55011 2007...

Page 20: ...15 16 in Height with adapter CC103 with XC103 3U 132 5mm 5 22 in CC105 with XC105 4U 177 0mm 6 97 in CC108 with XC108 5U 221 4mm 8 72 in Weight CC103 6 8 kg 15 0 lb CC105 7 3 kg 16 1 lb CC108 8 5 kg...

Page 21: ...s in mm Slots A B C D CC103 3 106 68 3 42 13 15 CC105 5 146 108 9 84 12 45 CC108 8 212 174 9 150 12 45 NOTE The front and rear mounting holes M4 are symmetrical User Manual Agilent Acqiris 3 5 and 8 s...

Page 22: ...imensions Figure 4 1 CC105 Crate with Rack mount All dimensions in mm Rack mount Height A CC103 XC103 3U 132 5 CC105 XC105 4U 177 0 CC108 XC108 5U 221 4 User Manual Agilent Acqiris 3 5 and 8 slot cPCI...

Page 23: ...4 APPENDICES 4 1 U1092A C31 XC103 Rack mount Adapter Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 22 of 28...

Page 24: ...4 2 U1092A C51 XC105 Rack mount Adapter Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 23 of 28...

Page 25: ...4 3 U1092A C81 XC108 Rack mount Adapter Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 24 of 28...

Page 26: ...4 4 XC114 XC116 XC119 Handles for Rack Mounted CC10X Crate Family Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 25 of 28...

Page 27: ...4 5 U1092A U1056A C32 C52 C82 XC113 XC115 XC118 Handles and Feet Specifications and Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 26 of 28...

Page 28: ...4 6 U1092A C01 U1056A A10 XC100 6U to 3U Slot Adapter Specifications and Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 27 of 28...

Page 29: ...4 7 U1092A C02 U1056A A11 XC200 6U Filler Plug in Specifications and Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 28 of 28...

Page 30: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: