Agilent Technologies ACQIRIS CC103 User Manual Download Page 13

3.

 

SPECIFICATIONS 

3.1.

 

Main Features 

The main features of the CC10X series include : 

 

3, 5, and 8 slot versions. They have horizontal slot orientation with a 

System Slot

 at the bottom and 2, 4, or 

Peripheral Slots 

above. 

 

CompactPCI (PICMG 2.0 R2.1) 6U and 3U module compatibility. The Backplane is equipped with P1 and 
P2 connectors. A CompactPCI 3U module must be used with the optional XC100 Slot Adapter. The crate 
accepts PXI modules, but does not provide PXI-specific features. 

 

Internal switch with locking lever for selection of V(I/O) to 5V or 3.3V. The standard version is shipped 
with V(I/O) set to 5V and 5V brilliant blue coding keys. On request we can deliver the crate with V(I/O) set 
to 3.3V and 3.3V cadmium yellow coding keys. 

 

Optimized cross-flow air circulation. Power supply and module slots are fully protected against over-
temperature. 

 

Compact design for bench-top and rack-mount installation with the optional rack-mount adapter. The rack-
mount adapter can be placed to either the front or the rear of the crate. 

 

Front and rear panel main power switches for easy access. 

 

Meets to IEEE 1101.10 standard for EMC compatibility and optimized cooling. 

 

Quality 270W, 400W, 600W, or 800W usable power supply with universal AC input, power factor 
correction, auto-voltage and auto-frequency ranging. 

 

Derating

 (DEG) and 

Supply Fall

 (FAL) signals provided from the power supply to backplane 

System Slot

 

(P2 connector). 

 

Tilt feet for bench-top application. 

 

66 MHz operation supported for the 3 and 5 slot versions ONLY. 

 

Internal switch for selection of forced 33 MHz PCI operation or choice of 33 MHz / 66 MHz based on 
modules present. 

 

User Manual: Agilent Acqiris 3-, 5-, and 8-slot cPCI Crates

 

                     

Page 12 of 28

 

Summary of Contents for ACQIRIS CC103

Page 1: ...cess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Dem...

Page 2: ...USER MANUAL AGILENT ACQIRIS 3 5 AND 8 SLOT CPCI CRATES...

Page 3: ...sumed for the use or the reliability of software firmware or any equipment that is not supplied by Agilent or its affiliated companies You can download the latest version of this manual from http www...

Page 4: ...6U modules 11 2 5 2 Installing 3U modules 11 2 5 3 Installing Filler Plug in 11 3 SPECIFICATIONS 12 3 1 Main Features 12 3 2 Power Supply 13 3 2 1 AC Input Specifications 13 3 2 2 DC Outputs Specifica...

Page 5: ...stalling the modules and operating the system 1 3 Organization of This Manual This manual is organized as follows Chapter 1 OUT OF THE BOX gives information you must know prior to using CC10X crates l...

Page 6: ...y an empty crate or handles need to be attached and two persons have to manipulate a loaded crate The smaller crates can be manipulated by one person WARNING If an instrument handle is damaged you sho...

Page 7: ...rack mount kits are available from Acqiris U1092A C31 XC103 RACK MOUNT ADAPTER for CC103 crate Height 3U 132 5mm U1092A C51 XC105 RACK MOUNT ADAPTER for CC105 crate Height 4U 177mm U1092A C81 XC108 R...

Page 8: ...in order to verify product performance All repairs replacement and spare parts are warranted for a period of 3 months Warranty extensions are available as an option In exercising this warranty Agilent...

Page 9: ...nt on all sides NEVER USE STYRENE PELLETS IN ANY SHAPE AS PACKAGING MATERIALS They do not adequately cushion the instrument or prevent it from moving in the shipping container Styrene pellets can also...

Page 10: ...WARNING Before connecting the crate to a power source read this chapter and the paragraph 1 5 Figure 2 1 Front view of the CC105 Figure 2 2 Rear view of the CC105 User Manual Agilent Acqiris 3 5 and...

Page 11: ...front panel and an other one on the rear panel of the CC10X For further information refer to the paragraph 3 6 3 Rack Mounting Dimensions and appendix 4 1 4 2 4 3 and 4 5 Specifications and Assembly I...

Page 12: ...ing the handles into place Tighten both front panel mounting screws to lock the module into place and insure proper grounding of the frame 2 5 2 Installing 3U modules CAUTION The XC100 6U to 3U Slot A...

Page 13: ...s flow air circulation Power supply and module slots are fully protected against over temperature Compact design for bench top and rack mount installation with the optional rack mount adapter The rack...

Page 14: ...thin the fuse holder on the rear panel All Fuses are Slow Blow 5x20mm CC103 T 4A H 250V CC105 T 6 3A H 250V CC108 low power T 6 3A H 250V CC108 and CC108 600 T 10A H 250V CC108 800 T 10A H 250 V for 1...

Page 15: ...W 12V 17A 204W 12V 17A 204W RMS Ripple 0 1 or 10mV whichever is greater 20MHz bandwidth Peak to Peak Noise 1 or 50mV whichever is greater 20MHz bandwidth Dynamic Response 2 or 100mV 25 load step Reco...

Page 16: ...ooling Capacity To be respected to ensure that the slot does not exceed the safe operating temperature CC103 3 slots 150W 50 C or 270 W 30 C CC105 5 slots 250W 50 C or 400 W 30 C CC108 8 slots 400W 50...

Page 17: ...slot connectors P1 and P2 3 3V P1 10 contacts 5V P1 8 contacts 12V P1 1 contact 12V P1 1 contact V I O P1 5 contacts P2 6 contacts GND P1 14 contacts P2 18 contacts Bus Frequency 66 MHz operation is...

Page 18: ...CK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 KEY AREA 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD...

Page 19: ...p 1 class A AS NZS CISPR 11 ICES NMB 001 This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme la norme NMB 001 du Canada Reference Standards Limit CISPR 11 2003 EN 55011 2007...

Page 20: ...15 16 in Height with adapter CC103 with XC103 3U 132 5mm 5 22 in CC105 with XC105 4U 177 0mm 6 97 in CC108 with XC108 5U 221 4mm 8 72 in Weight CC103 6 8 kg 15 0 lb CC105 7 3 kg 16 1 lb CC108 8 5 kg...

Page 21: ...s in mm Slots A B C D CC103 3 106 68 3 42 13 15 CC105 5 146 108 9 84 12 45 CC108 8 212 174 9 150 12 45 NOTE The front and rear mounting holes M4 are symmetrical User Manual Agilent Acqiris 3 5 and 8 s...

Page 22: ...imensions Figure 4 1 CC105 Crate with Rack mount All dimensions in mm Rack mount Height A CC103 XC103 3U 132 5 CC105 XC105 4U 177 0 CC108 XC108 5U 221 4 User Manual Agilent Acqiris 3 5 and 8 slot cPCI...

Page 23: ...4 APPENDICES 4 1 U1092A C31 XC103 Rack mount Adapter Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 22 of 28...

Page 24: ...4 2 U1092A C51 XC105 Rack mount Adapter Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 23 of 28...

Page 25: ...4 3 U1092A C81 XC108 Rack mount Adapter Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 24 of 28...

Page 26: ...4 4 XC114 XC116 XC119 Handles for Rack Mounted CC10X Crate Family Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 25 of 28...

Page 27: ...4 5 U1092A U1056A C32 C52 C82 XC113 XC115 XC118 Handles and Feet Specifications and Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 26 of 28...

Page 28: ...4 6 U1092A C01 U1056A A10 XC100 6U to 3U Slot Adapter Specifications and Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 27 of 28...

Page 29: ...4 7 U1092A C02 U1056A A11 XC200 6U Filler Plug in Specifications and Assembly Instructions User Manual Agilent Acqiris 3 5 and 8 slot cPCI Crates Page 28 of 28...

Page 30: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: