359
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_qpchannel.fm
CALL:QPCHannel
CALL:QPCHannel:LEVel[:RTCell][:SELected]?
CALL:QPCHannel:LEVel:RTPilot[:SELected]
Function
Queries the forward quick paging channel (QPCH) level relative to the cell power level.
The optional [:SELected] keyword in this command specifies that the frequency band being
set/queried applies to the current system type.
The QPCH channel is slotted (pulsed). When the state of the QPCH is on, OCNS is calculated
based on the channel power when QPCH is present in the signal. When QPCH is not present, the
output power is not fully calibrated.
Query
Range: 0 to -15 dB, NAN
Resolution: 0.01 dB
*RST Setting
-10 dB
Programming Example
OUTPUT 714;"CALL:QPCHANNEL:LEVEL:RTCELL:DIGITAL2000?"
Function
Sets/queries the forward quick paging channel (QPCH) level relative to the pilot level
The optional [:SELected] keyword in this command specifies that the frequency band being
set/queried applies to the current system type.
The QPCH channel is slotted (pulsed). The test set adjusts OCNS (orthogonal channel noise
simulator) to an appropriate level for the periods of time when the slotted QPCH signal is pulsed
on. When QPCH is pulsed off, the output level will not be fully calibrated.
Query
Range: +2 to -5 dB
Resolution: integer
*RST Setting
-3
Programming Example
OUTPUT 714;"CALL:QPCHANNEL:LEVEL:RTPILOT:SELECTED?" !queries the QPCH level relative to the pilot
level.