338
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_ocnsource.fm
CALL:OCNSource
CALL:OCNSource:LEVel[:SELected]?
Function
Queries the calculated level of the orthogonal channel noise simulator (OCNS).
The optional [:SELected] keyword in this command specifies that the OCNS level being queried
applies to the current system type.
The OCNS level is a calculated value used to balance the relative power levels of the following
channels to sum to 100%:
• OCNS
• Paging (PCH)
• Pilot (PICH)
• Sync (SCH)
• Fundamental (FCH)
• Supplemental (SCH)
• Quick Paging (QPCH)
If the contribution of OCNS is calculated to be -30 dB or less, the OCNS state is turned off.
Query
Range: 0 to -20 dB, NAN
Resolution: 0.01 dB
*RST Setting
NAN
Programming Example
OUTPUT 714;"CALL:OCNSOURCE:LEVEL?" !Queries the calculated OCNS level.