Applications

With one module the following applications can be set up, further explained in 
the 

Hardware part  chapter :

Stereo passive filtered system

Briged mode for single subwoofer (max 140Watt into 4 Ohms)

Mono/mid 2-way setup (t sub)

When two modules are used the following applications can be set up, also 
explained in 

Hardware part :

2-way active filtered stereo system

2 channel system with active subwoofer

2 channel system, both modules in bridge mode for more power

All setups are both possible with analogue and optional with the digital audio 
inputs SPDIF and USB.

Note that all setups have the ability to use an extra channel by connecting a 
active subwoofer to the subout. By this you will have the opportunity to build a 
3-way system.

Connections

Figure 1

Overview of the connections on the front of the AV dsp amp.

Function

1

Amplifier output, for slave speaker in stereo setup

4

Analogue input left channel

5

Analogue input right channel

6

Subwoofer output

- 4 -

Summary of Contents for AV dsp amp

Page 1: ...User Manual AV dsp amp...

Page 2: ...io input 8 Audio performance data 8 Remote control 8 Product overview 9 Hardware part 9 Software installation 11 Control panel 11 Filter design 12 Graph Area 13 Filter Definition Area 14 Settings wind...

Page 3: ...ding a digital audio board SPDIF stereo audio input Input sample rates up to 192kHz Link communication trough SPDIF link cable one cable for audio and link USB audio input Low signal to noise 104dB 3...

Page 4: ...ystem 2 channel system with active subwoofer 2 channel system both modules in bridge mode for more power All setups are both possible with analogue and optional with the digital audio inputs SPDIF and...

Page 5: ...R in 3 5mm max 4 5V 8a USB control input 9 Master trigger output slave trigger input Right channel trough 11 230 volt input Digital version only 2 SPDIF audio input 3 SPDIF audio output Audio trough f...

Page 6: ...board DSP digital signal processor Figure 1 shows the block diagram of the amplifier When two modules are used the second unit slaves to the first unit master through a link cable The link cable a ste...

Page 7: ...able doubles as a master slave link obviating the need for the mini jack cable The mini jack cable remains functional though and does not have to be removed Audio performance data MBW 20kHz unless oth...

Page 8: ...sp amp When your master is the left channel the slave will become the right channel When you want to set the master as right channel with analogue input you will have to change the input cinches left...

Page 9: ...t channel is linked trough so if you want the left channel to be linked trough you just switch left and right For digital sources the left and right channel are linked An example is given in the last...

Page 10: ...io device When the installation is done the connected window will appear and the connection light will turn green You can also manually make a connection by the connect button on the bottom right of t...

Page 11: ...to use one subwoofer but if you want to use a subwoofer on both sides you can set the subout to only use left or right input signal The last thing that can be controlled in this window is volume This...

Page 12: ...idual filtered driver responses and the sum Colour Function Blue thin Measured woofer response Green thin Measured midrange response Red thin Measured tweeter response Blue thick Filtered woofer respo...

Page 13: ...hannels have up to 12 biquads selected using the Biquad Section radio buttons in the middle The Subwoofer lineout has only 6 biquads sections for only simple filter settings To the right is a settings...

Page 14: ...may also be used for measuring the drivers provided the amplifier s output impedance is as low as the DSP unit s Importing response data Select the tab for the channel you want to import and click sel...

Page 15: ...good deal of interpretation but it is doable Important Avoid making any corrections for which no anechoic data is available If reflections are included they are guaranteed to dominate the measurement...

Page 16: ...nd for the midband peak dip combo of most midwoofer speakers Asymmetric Shelf Pole frequency and Q Zero frequency and Q Equalising the bottom end of closed box woofers with large magnets Boost Cut Cen...

Page 17: ...e its firmware when provides a new firmware version The firmware version of the module is shown in the statusbar of the filter design window and under About The firmware can be easily updated by USB t...

Page 18: ...akers connected Master 1 Plug in the power connector and switch the module to ON 2 Power up the module by the control panel or remote 3 Start the pc program filter design 4 Plug in the USB cable assum...

Page 19: ...w just leave it Auto detect Note that in auto detect the USB source is selected when the module is connected to the pc 8 Switch to the Filter design Window under view or press ctrl f 9 Fill in your bi...

Page 20: ...oad the filters to you module under Download or press ctrl F9 8 When download is completed you can power down the module and disconnect the USB cable 9 Master and Slave are now set up as a 2 channel s...

Page 21: ...ng system that can not detect the USB device 6 Set the system to the desired setup for this example stereo left because the left speaker holds the AV dsp amp module 7 Set the Subout control to L R bec...

Page 22: ...r filters at any time just repeat the steps of this example Technical data Supply voltage 230Volt AC 50Hz 10 Dimensions 225mmx83mmx350mm WxHxD Weight 4 3 kg Warranty The work carries warranty out for...