20
BU-0101704 R3
4.5. Bin Wall Cutout
An opening must be cut in the bin wall for the underfloor auger.
Cutting an opening in the bin can weaken the bin’s structure and may lead to bin collapse if
the instructions in this section are not accurately followed.
When installing the bin unload, consult the manufacturer for specific details on the bin wall cutout.
General points to consider are:
• Keep a minimum 45° angle between the center points of any two openings, such as an aeration fan (see
Figure 3.
Minimum Angle Between Openings
• Center the opening in the middle of the bin sheet, between two vertical bolt seams.
• Do not cut an opening through a vertical bolt seam between two sheets or a stiffener position.
• Cut the opening in a bin sheet at a location designated for discharge (see
and
Note
When measuring the opening, measure the dimension for the height of the cutout from the bottom
edge of the bin wall sheet.
• Cut the opening as tight as possible for the underfloor auger to pass through and do not have more than a
1/4” (6 mm) gap to the auger joint flange on any side.
• The vertical flange of the bottom bin angle may be cut flush to the sides of the opening to allow the
underfloor auger to fit through the opening.
EASYFLOW2 (100 SERIES) – FARM TUBE BIN UNLOAD SYSTEM