Jeti Tauro H3300LED Operator Manual
41
Agfa Graphics
Chapter 3
-
Step 07 When you observe lines in the rectangular pattern (top solid white block), you need to check
the grid pattern shown in Fig. Nozzle Issues Close Up Views. If a missing nozzle occurs, a line will be
missing in the grid pattern, which means a missing nozzle.
Note
: A naked eye can easily spot any nozzle issue as it affects the evenness of the color patch as
illustrated in the close up views in Fig.4-33.
White nozzle check pattern
Missing white nozzle close up
Fig. missing white nozzle close up
Fig.4-33: Nozzle Issues Close Up Views
-
Step 08 Check Primer heads nozzles (
see Procedure “How to Check the White Nozzles”
for more
details).
-
Step 09: Print the “Nozzle Check White” built in patterns to confirm functionality of the Primer
nozzles.
Note
: The use of the Agfa certified Tauro calibration media is not mandatory for this test. You can
print this test on any black or white media larger than the image size of 1020 X 720 mm². The test
patterns are similar to the white nozzle check and are checked the same way.
-
Step 10: When detecting a nozzle issue, you can purge the relevant Color bar again and reprint the
pattern.
-
Step 11: Proceed to “
Purge and Clean
”.
Revision 1.0
Summary of Contents for Jeti Tauro H3300LED Series
Page 2: ...B EC Declaration of Conformity Agfa Graphics Revision 1 0 ...
Page 32: ...Jeti Tauro H3300LED Operator Manual 24 Agfa Graphics Chapter 3 Revision 1 0 ...
Page 76: ...Jeti Tauro H3300LED Operator Manual 68 Agfa Graphics Chapter 5 Revision 1 0 ...
Page 77: ...Jeti Tauro H3300LED Operator Manual 69 Agfa Graphics Chapter 5 Revision 1 0 ...
Page 102: ...Jeti Tauro H3300LED Operator Manual 94 Agfa Graphics Chapter 6 Revision 1 0 ...
Page 105: ...Jeti Tauro H3300LED Operator Manual 97 Agfa Graphics Chapter 8 Revision 1 0 ...
Page 109: ...Revision 1 0 ...