TROUBLESHOOTING
09.3
Troubleshooting
11-04
RoGator 418
Electrical System (Continues)
Electrical system is inoperative
→
Corroded or loose battery
connections.
→
Sulphated batteries.
→
Defective fuse or defective
relay.
→
Defective ignition switch.
→
Defective earth switch.
→
Clean and tighten the con-
nections.
→
Check the battery open cir-
cuit voltage for 12.6 Volt.
Check the electrolyte level
and the specific gravity.
→
Check the fuses.
→
Contact Ag-Chem Europe
b.v. service centre.
→
Replace the earth switch.
Hydraulic System
PROBLEM
POSSIBLE CAUSE
CORRECTION
Complete hydraulic system does
not operate
→
Low oil level.
→
Restricted hydraulic filter.
→
Malfunctioning hydraulic
system.
→
Fill the system.
→
Replace the hydraulic oil
filter.
→
Contact Ag-Chem Europe
b.v. service centre.
Hydraulic system oil overheats
→
Oil level to high / low.
→
Oil cooling system / radia-
tor restricted.
→
Blower not running.
→
Blocked oil filter element.
→
Rectify the oil level.
→
Clean the oil cooling system/
radiator.
→
Disconnect engine blower
plug.
→
Replace the filter.
Brakes
PROBLEM
POSSIBLE CAUSE
CORRECTION
Parking brake is inoperative.
→
Worn brake pads.
→
Hydraulic pressure drop.
→
Replace the brake pads.
→
See Troubleshooting Hy-
draulic System.
Service brake is inoperative.
→
Problems with the hydraulic
system.
→
Refer to "Hydraulic System".
Steering
PROBLEM
POSSIBLE CAUSE
CORRECTION
Vehicle rides rough.
→
Incorrect seat adjustment.
→
Faulty seat suspension.
→
Tyre inflation pressure too
high.
→
Excessive speed.
→
Adjust seat ride and damp-
ener.
→
Contact Ag-Chem Europe
b.v. service centre.
→
Inflate the tyres correctly.
→
Reduce speed.