Harvest Tec
outputs.
System leaks product out of tips after
shut down.
1. Dirty or defective check valves.
1. Clean or Replace.
Terminal reads under or over power.
1. Verify with mult-meter actual
voltage. Voltage range should be
between 12-14 volts.
1. Clean connections and make sure
applicator is hooked to battery. See
Diagnostics section of manual.
System does not pause at the end of a
row.
1. Short in cable.
2. Damaged sensor.
3. Bad alignment of sensors
1. Replace cable.
2. Replace sensor
3. Check 474 manual for alignment
instructions
Bale rate displays zero.
1. Bale rate sensors are reversed.
2. Short in cable.
3. Damaged sensor.
1. Switch the sensors next to the star
wheel.
2. Replace cable.
3. Replace sensor.
Display will not power up.
1. Connection broke between the
display and the PIP.
2. Short in display cable.
1. Check, clean, and tighten
connections.
2. Replace cable.
Display is too dark or light
1. Change in temperature or light
conditions.
1. Use the monitors contrast control.
Display is locked up/froze.
1. CAN communication not
responding.
2. Broke connection between the
display and PIP or Pump control
and PIP.
1. Check connections at PIP and Pump
controller including the terminating
resistors.
2. Check, clean, and tighten
connections.
3. Power unit down and restart after
steps 1 & 2 are complete.
Display powers up when key is turned
and will not go to the Main Menu screen.
1. CAN communication not
responding.
2. Broke connection between the
display and PIP or Pump control
and PIP.
1. Check connections at PIP and Pump
controller including the terminating
resistors.
2. Check, clean, and tighten
connections.
3. Power unit down and restart after
steps 1 & 2 are complete.
Display is locked up/froze and pumps
continue to run.
1. CAN communication not
responding.
2. Broke connection between the
display and PIP or Pump control
and PIP.
1. Check connections at PIP and Pump
controller including the terminating
resistors.
2. Check, clean, and tighten
connections.
3. Power unit down and restart after
steps 1 & 2 are complete.
Display says PAC error
1. The PIP and Pump controller
are not communicating.
2. Broke connection between the
display and PIP or Pump control
and PIP.
1. Check all connections at PIP and
Pump controller including terminating
resistors.
2. Check, clean, and tighten
connections.
Summary of Contents for HayBoss G2 596
Page 11: ...For AGCO part cross reference visit www harvesttec com system html 11 Manual Mode...
Page 12: ...For AGCO part cross reference visit www harvesttec com system html 12 Diagnostics...
Page 13: ...For AGCO part cross reference visit www harvesttec com system html 13 Setup Mode...
Page 14: ...For AGCO part cross reference visit www harvesttec com system html 14 Setup Mode Continued...
Page 15: ...For AGCO part cross reference visit www harvesttec com system html 15 Job Records...
Page 62: ...62 NOTES...