Tank lid cleaning:
Before cleaning the tank lid all personal protective equipment must be worn (Face shield
or goggles, chemically resistant apron, boots, and gloves).
The tank lid is located on the top of the tank. Use the supplied handle on the tank to secure your person and
use the other hand to remove any debris from the top of the tank. Unscrew the tank lid and bring down ground
level. Use compressed air clean out the tank screen (D). If the screen cannot be thoroughly cleaned with
compressed air, replace fitting (005-9022B3). Once the screen is cleaned reinstall the cover.
Dielectric grease connections:
Disconnect all harnesses on the applicator, clean the connections, and
repack with dielectric grease.
Rebuild pumps:
If Diagnostic or Manual mode show that the pumps are running lower than normal, a pump
rebuild may be necessary. To do this rebuild the pump must be removed from the pump manifold. Pump
rebuild is part no. 007-4581. A service pack that includes pump rebuilds and check valves is available from
your local dealer.
Verify that the ball valve is turned off. Before working around the pumps all personal protective equipment
must be worn (Face shield or goggles, chemically resistant apron, boots, and gloves). Remove pump from
manifold. Follow rebuild instructions supplied with pump rebuild kit. Reinstall after rebuild is complete.
Battery connections:
Follow the batteries safety warnings and clean the battery connections. If the
connections cannot be cleaned, replace harness.
Check Valves:
Before servicing the check valves all personal protective equipment must be worn (Face
shield or goggles, chemically resistant apron, boots, and gloves).
Verify the ball valve is turned off before service the check valves. Replace the intake check valves by the
pumps (002-4566F) and the discharge check valves by the tip (004-1207VB).
Miscellaneous maintenance:
1. Depending on the product being used, the system may need to be flushed with water at a regular
interval (consult with manufacturer of the chemical.) If Harvest Tec product is being used, flushing is
not necessary.
2. Although the pump can run dry, extended operation of a dry pump will increase wear. Watch the
preservative level in the tank.
3. If you are using bacterial inoculants, flush your system daily after every use.
D
Summary of Contents for HayBoss G2 596
Page 11: ...For AGCO part cross reference visit www harvesttec com system html 11 Manual Mode...
Page 12: ...For AGCO part cross reference visit www harvesttec com system html 12 Diagnostics...
Page 13: ...For AGCO part cross reference visit www harvesttec com system html 13 Setup Mode...
Page 14: ...For AGCO part cross reference visit www harvesttec com system html 14 Setup Mode Continued...
Page 15: ...For AGCO part cross reference visit www harvesttec com system html 15 Job Records...
Page 62: ...62 NOTES...