4
AGC Stopray SMART
–
Processing Guide
–
Version 4.1
–
May 2020
1.
PRODUCTS
This Processing Guide concerns the Stopray SMART products: Stopray SMART 51/33, Stopray
SMART 30/20 and Stopray SMART 32T.
The Stopray SMART products can be used either annealed (so without heat treatment) or with heat
treatment (thermal toughening or heat strengthening).
The Stopray SMART products can be used in this configuration:
I.
RECEPTION AND STORAGE
1.
Unloading
The packs of glass must be inspected on arrival. AGC shall accept no liability for coating defects arising
after delivery or during handling, processing or installation of the finished product in the building if this
procedure is not followed:
The rack must be positioned on perfectly level ground.
Use the appropriate handling equipment.
The grab must be perfectly centered.
Avoid damaging the protective packaging whilst handling.
The glass must be stored on appropriate racks.
All recommendations given in this Processing Guide shall be strictly followed.
General comments:
Clamps, slings, lifting beams and other handling equipment must comply with prevailing regulations
and be approved by the relevant authorities.
Ensure the safety of personnel at all times. Keep all unnecessary personnel out of the handling
area. Wear appropriate personal protective equipment.
Personnel must have received the required training.
Due to the fact that the interlayer powder is removed during the washing process, we recommend
placing micro-suction pads
around the edge of each sheet of glass in order to prevent contact between
the glass and the coatings. Paper with a neutral pH can also be used, for example, for large pieces.
The personnel responsible for handling the glass must wear clean gloves
suitable for handling coated
glass.
Configuration
IGU with coating
facing cavity
Laminated with coating
in contact with PVB
interlayer
SMART 30/20
Yes
No
SMART 51/33
Yes
Yes
SMART 32T
Yes
No