background image

INSTALLATION CLEARANCES OF COMBUSTBLE CABINETS ADJACENT TO

RANGE AGA TOTAL/ DUAL CONTROL (WITH MODULE SHOWN)

Installation Clearance of Combustible Cabinets Adjacent to Range

1/2” CLEARANCE TO THE BACK OF THE RANGE MAY BE OBTAINED WHEN INSTALLING THE APPLIANCE

AGAINST A NON-COMBUSTIBLE WALL OR IF THE WALL BEHIND THE RANGE IS DEEMED COMBUSTIBLE THEN

THE MINIMUM SPACING FROM THE BACK OF THE APPLIANCE TO THE NEAREST COMBUSTIBLE WALL IS 1 

1

/

2

(38mm).

8

Fig. 3

DESN 517032

Summary of Contents for DC3M

Page 1: ...may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT DO YOU DO IF YOU SME...

Page 2: ...grated Module Gas Hob TC3M DC3M Specification AGA Total Control TC5 Dual Control DC5 7 with TC DC Integrated Module Gas Hob TC5M DC5M Installation of Clearances of Combustible Cabinets adjacent to 8 r...

Page 3: ...d electrode TERRE DE PROTECTION Pour marquer bornes destin es tre raccord es un conducteur de protection ext rieur contre les chocs clectiques en cas de d faut d isolement ou pour marquer la borne de...

Page 4: ...STRUCTIONS SHOULD BE LEFT WITH THE RANGE AND THE USER TO RETAIN FOR FUTURE REFERENCE GENERAL INSTALLATION REQUIREMENTS The installation of the range must be in accordance with the relevant requirement...

Page 5: ...e latest edition of the Local and National Wiring Regulations Remember that an excess of cable length is required for the possible withdrawal of the range A electrical socket type 14 30R must be provi...

Page 6: ...ed overall by 3 8 10mm beyond the figures quoted This allows safe margin to take into account the natural dimensional variations found in major castings In particular the width across an appliance rec...

Page 7: ...overall by 3 8 10mm beyond the figures quoted This allows safe margin to take into account the natural dimen sional variations found in major castings In particular the width across an appliance rece...

Page 8: ...Combustible Cabinets Adjacent to Range 1 2 CLEARANCE TO THE BACK OF THE RANGE MAY BE OBTAINED WHEN INSTALLING THE APPLIANCE AGAINST A NON COMBUSTIBLE WALL OR IF THE WALL BEHIND THE RANGE IS DEEMED CO...

Page 9: ...HEAT 12 000 Btu hr 10 600 Btu hr 6 150 Btu hr 6 150 Btu hr INPUT 3 5 kW 3 1 kW 1 8 kW 1 8 kW 250g h 221g h 128g h 128g h 0 5l h 0 43l h 0 26l h 0 26l h INJECTOR MARKING 105 94 72 75 PRESSURE POINT POS...

Page 10: ...i 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply system at test pressures equal...

Page 11: ...assembled condition 11 INSTALLATION SEQUENCE AND PROCEDURE Installation must be to Local and National Wiring Regulations and carried out by a Qualified Engineer Having ensured all space requirements...

Page 12: ...11 64 4 5mm between plinths Fig 5 DESN 516859 11 64 4 5 mm SCREW HEAD DEPTH Check with a spirit level that the plinth is correct and using a straight edge check that both plinths are aligned along th...

Page 13: ...5 mm GAP FOR AGA TC5 DC5 MODULE ONLY 6 Attach Module plinth to the AGA Total Dual Control plinth using 2 M6 screws and washers provided See Fig 7 or 7A Slide front jointing bracket into place over tw...

Page 14: ...rome buttons and the four top plate retaining screws 2 each side c Remove two screws from control panel one from left hand hole and one from centre hole See Fig 8 d Pull top plate forward slightly and...

Page 15: ...or wire lead on the range Do Not ground to gas pipe Failure to follow these instructions could result in death or serious injury l A four wire single phase 240 volt 60 Hz AC only electrical supply is...

Page 16: ...ass terminal nuts attached to the inside of the terminal block cover Be sure nuts are installed tight 14 Complete electrical connection L1 WHITE NEUTRAL GREEN GROUND L2 Fig 9 DESN 511752 16 9 Remove t...

Page 17: ...iance is aligned squarely with the plinth Check that the Module front plate and AGA Total Dual Control front plate are the same height and that the overlap strips correspond correctly If not adjustmen...

Page 18: ...ot be less than 9 16 15mm diameter Connection is made to the 9 16 15mm compression fitting located just below the hotplate level on the rear left hand side of the cooker a Mark off appropriate positio...

Page 19: ...e minimum gas inlet pressure at the appliance must not be less than 5 w g Natural Gas and 11 wg L P Gas to enable the correct manifold pressure to be obtained NOTE The regulator is pre set for either...

Page 20: ...y screw the top plate down with 4 retaining screws 18 Verify that the two plates are level then proceed with tightening down 19 Fit the Module handrail bracket over the fixing stud located on the top...

Page 21: ...on the end cap O rings may ease fitment 23 Finally fit the plinth facia to the magnets on the front of the plinth making sure that the right hand side of the Module plinth facia sits against the left...

Page 22: ...wards slightly and lift up at the front Support top plate and disconnect the wiring to the neons Remove top plate 5 Lay the top plate on its top face suitably protected 6 Re assemble in reverse order...

Page 23: ...by removing 2 screws See Fig 20 7 Re assemble in reverse order ensuring that the sealing ring is correctly located between the new tap and the gas rail Rewire as circuit diagram 8 Check for gas sound...

Page 24: ...Fig 15 DESN 511617 BURNER CAP RETAINING LUGS Fig 15A DESN 513513 DESN 513898 Fig 15B 24...

Page 25: ...Remove left hand and centre grommets from the control panel to gain access to the fixing screws Remove two screws from control panel one from left hand hole and one from centre hole See Fig 8 d Pull...

Page 26: ...Fig 17 Fig 18 DESN 511649 DESN 511650 26...

Page 27: ...Fig 19 Fig 20 DESN 511651 DESN 511652 GAS RAIL SUPPORT BRACKET SCREWS GAS RAIL SUPPORT BRACKET SCREWS GAS TAP TUBE NUT GAS RAIL TUBE NUT 27...

Page 28: ...RING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING NOTE 1 IGNITION SWITCHES AND THERMOSTATS ARE SHOWN IN THE OFF POSITION WITH THE APPLIANCE COLD AND FAN OV...

Page 29: ...AGA TC DC INTEGRATED MODULE GAS HOB CIRCUIT DIAGRAM 29...

Page 30: ...A Service or contact your authorised distributor stockist l Your cooker must only be serviced by a Qualified Engineer from an authorised distributor or stockist l Do not alter or modify the cooker l O...

Page 31: ...31...

Page 32: ...16 754 9690 Toll Free Telephone 800 223 3900 With AGA Marvel s policy of continuous product im provement the Company reserves the right to change specifications and make modifications to the appliance...