Report Number: B30804208-E
August 12, 2003
Page 28
Rev. 00
14 SECTION 4 IEC 61000-4-3 (RADIATED ELECTROMAGNETIC FIELD)
RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST
Port
:
Enclosure
Basic
Standard
:
IEC 61000-4-3
Requirements
:
3 V/m / with 80% AM. 1kHz Modulation.
Performance
Criteria
:
A (Standard Require)
Tester
:
George Kuo
Temperature :
26
o
C
Humidity :
54%
Pressure :
1019mbar
Block Diagram of Test Setup:
0.8m
Power Amp
Signal
Generator
EUT Monitoring by
using a camera
Control Room
7x3x3 Chamber
EUT &
Support Units
PC Controller to control
S.G. & PA as well as
forward power
3 meter
1.5 meter
Summary of Contents for EM989