Report Number: B30804208-E 
August 12, 2003

 

 

Page 7 

 
 

Rev. 00 

 

4 PRODUCT 

INFORMATION 

Housing Type:

 

Plastic 

EUT Power Rating:

 

100-240VAC, 50/60Hz, 1.2A 

AC power during Test: 

230VAC/50Hz 

AC Power Cord Type: 

Unshielded, 1.8m (Non-detachable) 

OSC/Clock Frequencies

 

12MHz 

 

 

Power Board Manufacturer: 

Compal 

Model: 

VP-908 

Main Board Manufacturer: 

Compal 

Model: 

VL-720 

Key Board Manufacturer: 

Compal 

Model: 

VK-908 

LCD Panel Manufacturer: 

FUJITSU 

Model: 

FLC48SXC8V-10 

VGA Cable Type: 

Shielded, 1.8m with two cores (Detachable) 

DVI Cable Type: 

Shielded, 1.8m with a core (Detachable) 

Audio Cable Type: 

Shielded, 1.8m (Detachable) 

I/O Port of EUT 

I/O Port Type 

Q’TY 

TESTED WITH 

1).  Video In Port (VGA) 

2).  Video In Port (DVI) 

3).  Audio In Port 

4).  Audio Out Port 

Summary of Contents for EM989

Page 1: ...61000 4 5 1995 IEC 61000 4 6 1996 IEC 61000 4 8 1993 IEC 61000 4 11 1994 PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS Prepared for Compal Electronics Inc No 581 Jui Kuang Rd Neihu Taipei 114...

Page 2: ...Compatibility Directive 89 336 EEC Amended by 92 31 EEC 93 68 EEC 98 13 EC For the evaluation regarding the Electromagnetic Compatibility 89 336 EEC Amended by 92 31 EEC 93 68 EEC 98 13 EC the followi...

Page 3: ...ST TRANSIENTS BURST 31 16 SECTION 6 IEC 61000 4 5 SURGE IMMUNITY 33 17 SECTION 7 IEC 61000 4 6 CONDUCTED DISTRBANCE INDUCED RADIO FREQUENCY FIELD 35 18 SECTION 8 IEC 61000 4 8 POWER FREQUENCY MAGNETIC...

Page 4: ...viation None Condition of Test Sample Normal Final Result Pass Worst Data See below Test Item Freq MHz Measured Data Margin MuC Remark Radiated Emission 65 56 27 7 dB m 2 3 dB 3 3498 dB Conducted Emis...

Page 5: ...03 Equipment Under Test LCD Monitor Model Number EM989 Serial Number N A Type of Test EMC Directive 89 336 EEC for CE Marking Technical Standards EN 55022 1998 A1 2000 EN 61000 3 2 2000 EN 61000 3 3 1...

Page 6: ...I test program was loaded and executed in Windows 2000 mode 2 Data was sent to EUT filling the screen with upper case of H patterns 3 Test program sequentially exercised printer and modem then sent H...

Page 7: ...rd Manufacturer Compal Model VP 908 Main Board Manufacturer Compal Model VL 720 Key Board Manufacturer Compal Model VK 908 LCD Panel Manufacturer FUJITSU Model FLC48SXC8V 10 VGA Cable Type Shielded 1...

Page 8: ...N A N A GITON Unshielded 1 25m N A For Harmonic Flicker Test Only No Equipment Model Serial FCC ID Trade Name Data Cable Power Cord 1 PC EVO D300 6K1BKF83F0ZZ FCC DoC Compaq N A Unshielded 1 8m 2 Mode...

Page 9: ...rument Tolerance All measuring equipment is in accord with ANSI C63 4 and CISPR 22 requirements that meet industry regulatory agency and accreditation agency requirement Ground Plane Two conductive re...

Page 10: ...MCO 2075 2 9707 2604 N C R N C R Controller EMCO 2090 N A N C R N C R RF Switch ANRITSU MP59B M54367 N C R N C R Site NSA C C N A N A 08 31 2002 08 30 2003 Decoupling Network FISCHER CUSTOM COMMUNICA...

Page 11: ...00 4 5 EQUIPMENT TYPE MFR MODEL NUMBER SERIAL NUMBER LAST CAL CAL DUE Surge Tester HAEFELY TRENCH PSUGER 4010 583 334 71 09 03 2002 09 02 2003 CS test 61000 4 6 EQUIPMENT TYPE MFR MODEL NUMBER SERIAL...

Page 12: ...All support equipment received power from a second LISN supplying power of 110VAC 60Hz if any 6 The EUT test program was started Emissions were measured on each current carrying line of the EUT using...

Page 13: ...of the worst case condition s was reported on the Summary Data page Data Sample Freq MHz Q P Raw dBuV Average Raw dBuV Q P Limit dBuV Average Limit dBuV Q P Margin dB Average Margin dB Note x xx 43 95...

Page 14: ...the test are shall drape to the floor be fitted with ferrite clamps or ferrite tubes placed on the floor at the point where the cable reaches the floor and then routed to the place where they leave th...

Page 15: ...ssion level and compare reading to the applicable limit and only Q P reading is presented 4 The test data of the worst case condition s was reported on the Summary Data page Data Sample Freq Raw Corr...

Page 16: ...OF TEST SETUP System Diagram of Connections between EUT and Simulators EUT LCD Monitor Trade Name Compal Model Number EM989 Power Cord Unshielded 1 8m LCD Monitor EUT 1 PC 2 Modem 3 Printer 4 PS 2 Key...

Page 17: ...Report Number B30804208 E August 12 2003 Page 17 Rev 00 For Harmonic Flicker Test Only LCD Monitor EUT 1 PC 2 Modem 3 Printer 4 PS 2 Keyboard 5 PS 2 Mouse DVI Cable x 1 VGA Cable x 1 Audio Cable x 1...

Page 18: ...V dBuV dBuV dB dB 0 155 46 20 65 70 55 70 19 50 L1 6 202 31 90 60 00 50 00 28 10 L1 10 247 27 80 60 00 50 00 32 20 L1 12 462 28 90 60 00 50 00 31 10 L1 14 586 30 00 60 00 50 00 30 00 L1 14 941 32 20 6...

Page 19: ...tor Function Quasi Peak Temperature 30o C Humidity 62 RH The chart below shows the highest readings taken from the final data Freq Raw Corr Emiss Limits Margin Data Factor Level MHz dBuV dB m dBuV m d...

Page 20: ...Function Quasi Peak Temperature 30o C Humidity 62 RH The chart below shows the highest readings taken from the final data Freq Raw Corr Emiss Limits Margin Data Factor Level MHz dBuV dB m dBuV m dB 1...

Page 21: ...st Result Pass Note According to clause 7 of EN 61000 3 2 2000 equipment with a rated power of 75W or less no limits apply The test result is only for reference VOLTAGE FLUCTUATION FLICKER MEASUREMENT...

Page 22: ...Report Number B30804208 E August 12 2003 Page 22 Rev 00...

Page 23: ...Report Number B30804208 E August 12 2003 Page 23 Rev 00...

Page 24: ...000 4 2 Test Level 8 kV Air Discharge 4 kV Contact Discharge 4 kV Indirect Discharge Performance Criteria B Standard Require Tester George Kuo Temperature 26o C Humidity 54 Pressure 1019mbar Block Dia...

Page 25: ...e As per IEC 61000 4 2 2001 with two 470k bleed resistors cable is connected between the EUT and HCP during the test applicable for power ungrounded or battery operating unit only The electrostatic di...

Page 26: ...Report Number B30804208 E August 12 2003 Page 26 Rev 00 The Tested Points of EUT Photo 1 of 3 Photo 2 of 3...

Page 27: ...Report Number B30804208 E August 12 2003 Page 27 Rev 00 Photo 3 of 3...

Page 28: ...dard IEC 61000 4 3 Requirements 3 V m with 80 AM 1kHz Modulation Performance Criteria A Standard Require Tester George Kuo Temperature 26o C Humidity 54 Pressure 1019mbar Block Diagram of Test Setup 0...

Page 29: ...double specified level 6V m at 4 steps 6 From the result of pre test in step 5 choice the worst side of EUT for final test from 80 MHz to 1000 MHz at 1 steps 7 Recording the test result in following t...

Page 30: ...iteria B The apparatus continues to operate as intended after the test No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the app...

Page 31: ...Y TEST Port On Power Supply Lines Basic Standard IEC 61000 4 4 Requirements 1 kV for Power Supply Line Performance Criteria B Standard Require Tester George Kuo Temperature 26o C Humidity 54 Pressure...

Page 32: ...hod Result Pass Fail L 1 Direct Pass N 1 Direct Pass PE 1 Direct Pass L N 1 Direct Pass L PE 1 Direct Pass N PE 1 Direct Pass L N PE 1 Direct Pass Performance Result Criteria A The apparatus continues...

Page 33: ...TEST Port Power Cord Basic Standard IEC 61000 4 5 Requirements 1 kV Line to Line 2 kV Line to Ground Performance Criteria B Standard Require Tester George Kuo Temperature 24o C Humidity 54 Pressure 1...

Page 34: ...Positive Capacitive Pass L1 L2 1 Negative Capacitive Pass L1 PE 2 Negative Capacitive Pass L2 PE 2 Negative Capacitive Pass Performance Result Criteria A The apparatus continues to operate as intende...

Page 35: ...ION 7 IEC 61000 4 6 CONDUCTED DISTRBANCE INDUCED RADIO FREQUENCY FIELD CONDUCTED DISTRBANCE INDUCED RADIO FREQUENCY FIELD IMMUNITY TEST Port AC Port Basic Standard IEC 61000 4 6 Requirements 3 V with...

Page 36: ...The apparatus continues to operate as intended No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the apparatus is used as inten...

Page 37: ...Y TEST POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST Port Enclosure Basic Standard IEC 61000 4 8 Requirements 1 A m Performance Criteria A Standard Require Tester George Kuo Temperature 26o C Humidity...

Page 38: ...tion X Y Z Orientation Field Result Pass Fail Remark X 1A m Pass Y 1A m Pass Z 1A m Pass Performance Result Criteria A The apparatus continues to operate as intended No degradation of performance or l...

Page 39: ...0 45 90 135 180 225 270 315 degrees Test Level UT Reduction Duration periods Performance Criteria 5 95 0 5 B Voltage Dips 70 30 25 C Test Level UT Reduction Duration periods Performance Criteria Volta...

Page 40: ...ge Interruptions Test Level UT Reduction Duration periods Observation Meet Performance Criteria 0 100 250 EUT shut down but can be auto recovered as the events disappear B Normal No any functions degr...

Page 41: ...Report Number B30804208 E August 12 2003 Page 41 Rev 00 20 APPENDIX 1 PHOTOGRAPHS OF TEST SETUP...

Page 42: ...Report Number B30804208 E August 12 2003 Page 42 Rev 00 20 1 LINE CONDUCTED EMISSION TEST EN 55022 Front View Back View...

Page 43: ...Report Number B30804208 E August 12 2003 Page 43 Rev 00 20 2 RADIATED EMISSION TEST EN 55022 Front View Back View...

Page 44: ...Report Number B30804208 E August 12 2003 Page 44 Rev 00 20 3 POWER HARMONIC VOLTAGE FLUCTUATION FLICKER TEST EN 61000 3 2 EN 61000 3 3...

Page 45: ...Report Number B30804208 E August 12 2003 Page 45 Rev 00 20 4 ELECTROSTATIC DISCHARGE TEST IEC 61000 4 2...

Page 46: ...Report Number B30804208 E August 12 2003 Page 46 Rev 00 20 5 RADIATED ELECTROMAGNETIC FIELD IEC 61000 4 3...

Page 47: ...Report Number B30804208 E August 12 2003 Page 47 Rev 00 20 6 FAST TRANSIENTS BURST TEST IEC 61000 4 4...

Page 48: ...Report Number B30804208 E August 12 2003 Page 48 Rev 00 20 7 SURGE IMMUNITY TEST IEC 61000 4 5...

Page 49: ...Report Number B30804208 E August 12 2003 Page 49 Rev 00 20 8CONDUCTED DISTURBANCE INDUCED BY RADIO FREQUENCY FIELDS TEST IEC 61000 4 6...

Page 50: ...Report Number B30804208 E August 12 2003 Page 50 Rev 00 20 9 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST IEC 61000 4 8...

Page 51: ...Report Number B30804208 E August 12 2003 Page 51 Rev 00 20 10 VOLTAGE DIPS INTERRUPTION TEST IEC 61000 4 11...

Page 52: ...Report Number B30804208 E August 12 2003 Page 52 Rev 00 21 APPENDIX 2 PHOTOGRAPHS OF EUT...

Page 53: ...Report Number B30804208 E August 12 2003 Page 53 Rev 00 Front View of EUT Back View of EUT...

Page 54: ...Report Number B30804208 E August 12 2003 Page 54 Rev 00 Left View of EUT Right View of EUT...

Page 55: ...Report Number B30804208 E August 12 2003 Page 55 Rev 00 Bottom View of EUT I O Port of EUT...

Reviews: