Technical specifications
Table 1: Technical specifications control unit
Parameter
Value
General specifications
Dimensions housing
(W x H x D)
100 x 188 x 65 mm
Length of probe ca-
ble
15 m
Housing material
Plastic, ABS
Operating temperature range
Ambient
0 °C to +45 °C
Storage
-5 °C to +80 °C
Supply voltage
Nominal voltage
AC 230 V ± 10 %
Nominal power
5 VA
Electrical safety
Protection class
II
(EN 60730)
Degree of protection
IP 54 (EN 60529; as delivered)
Electromagnetic compatibility (EMC)
Interference
EN 61000-6-4
Noise immunity
EN 61000-6-2
Table 2: Technical specifications universal submersible probe
Parameter
Value
General specifications
Dimensions (Ø x L)
24 x 53 mm
Weight
415 g
Length of probe cable
6 m
Pressure range
0-400 mbar
Accuracy*
≤
± 0.5 % FSO, IEC 60770
Temperature error
≤
± 0.3 % FSO, 10°K