13
Mounting
EN
DIT 10
5.4
Electrical connection
Verify that the the moisture-proof junction box is closed in such a way that
it is water-tight.
Verify that the moisture-proof junction box is closed in such a way that it
is
not
air-tight.
5.4.1
Connection diagram
1. Route the cable of the pressure sensor and the control unit to the mois-
ture-proof junction box.
2. Connect the cables using the terminal strip.
Verify that you connect wires of the same colour.
3. Close the moisture-proof junction box.
NOTICE
INCORRECT HANDLING
•
Verify that the transparent hose from the pressure sensor is not closed or
bent.
Failure to follow these instructions can result in equipment damage.
A. Cable from control unit
B. White (U+)
C. Green (signal)
D. Brown (U-)
E. Yellow/black (shield)
F. Terminal strip
G. Cable from pressure sensor
A
B
C
D
E
F
G
B
C
D
E