29
Maintenance
EN
RG 210
8
Maintenance
8.1
Maintenance intervals
8.2
Maintenance activities
Replacing the mains fuse F1
1. Loosen the two housing screws.
2. Remove the grey upper part of the housing from the black base.
3. Remove the grey cover from the upper part of the housing.
4. Pull the printed circuit board out of the upper part of the housing.
5. Replace the mains fuse
F1
, see chapter "Technical specifications".
6. Push the printed circuit board into the upper part of the housing.
7. Fit the grey cover into the upper part of the housing.
8. Push the upper part of the housing onto the black base.
9. Tighten the two housing screws.
10.Apply mains voltage.
When
Activity
Annually
Perform a function test.
Verify that the probes are free from deposits.
Replace the probes if you detect deposits.
Monthly
Verify that the control unit and its environment are
always clean, accessible and easy to oversee.
Every five years
Replace the probes.
DANGER
ELECTRIC SHOCK CAUSED BY LIVE PARTS
•
Disconnect the mains voltage supply before performing the work and ensure
that it cannot be switched on.
Failure to follow these instructions will result in death or serious injury.
Summary of Contents for 53206
Page 10: ...10 Produktbeschreibung DE RG 210 C Sockel D Gehäuseoberteil Abbildung 1 Signalteil C D ...
Page 12: ...12 Produktbeschreibung DE RG 210 4 3 Abmessungen 113 mm 53 mm ...
Page 42: ...10 Product description EN RG 210 C Base D Upper part of housing Fig 1 Control unit C D ...
Page 44: ...12 Product description EN RG 210 4 3 Dimensions 113 mm 53 mm ...
Page 76: ...12 Description du produit FR RG 210 4 3 Dimensions 113 mm 53 mm ...