AFL FOCIS Duel User Manual Download Page 27

27

On FOCIS Duel

 

Turn your FOCIS Duel unit off .

 

Using the supplied USB cable, connect the micro-USB port on your FOCIS Duel unit with a USB port 
on your PC .

 

Verify FOCIS Duel powers up and displays:

 

Mass Storage

 

Video

 

Select the Mass Storage mode .

On PC 

 

Select ‘My Computer’ . 

 

Verify that device labeled ‘PROBE (E:\)’ appears in My Computer window  

Note:

 drive letter assigned to PROBE device may be different .

 

Double-click PROBE (E:\) to view contents of the FOCIS Duel internal memory .

 

Double-click on RESULTS folder .

 

Drag, copy, or move some or all of the results to your PC .

 

When finished, disconnect USB cable and turn off FOCIS Duel (since FOCIS Duel will remain on and 
return to normal operation if USB cable simply disconnected .)

Uploading Inspection Results to a PC 

Inspection Reporting using TRM

®

 2.0

Port 1: Sharing Captured Test Results

On PC 

 

Install and run TRM 2 .0

 

Select Report Wizard

 

Navigate to uploaded FOCIS Duel Results .

 

Select entire [Cable] for all results .

 

Select individual fiber for single result .

 

Select desired inspection template (2 or 12 results per page) .

 

Select Finish and print or save as PDF file .

Summary of Contents for FOCIS Duel

Page 1: ...FOCIS Duel Fiber Optic Connector Inspection System User Guide www AFLglobal com or 800 321 5298 603 528 7780 Test Inspection...

Page 2: ...y Installing and Removing Adapter Tips 10 Port 2 Functionality 11 Inspection Live Image Mode 11 Port 1 Functionality 12 Live Image Mode Features 12 Capture Key Operation 12 Captured Image Mode Feature...

Page 3: ...ting New Jobs Cables Files 24 Deleting Jobs Cables Files 24 Port 1 Using FOCIS Duel with FOCIS App 25 Port 1 Sharing Captured Test Results 26 Sending Captured Results to FlexTester FlexScan 26 Configu...

Page 4: ...harmful to eyes WARNING Use only the specified AC adapter Use of another type of AC adapter can damage the instrument and create the danger of fire and electrical shock WARNING To avoid the danger of...

Page 5: ...automation platform aeRos aeRos is an open cloud based workflow management platform that facilitates two way communication and data exchange from engineering to project management to your technician...

Page 6: ...an authorized AFL repair facility or when it has been subjected to misuse negligence or accident In no case shall AFL liabilities exceed the original purchase price Repair Services Please contact cus...

Page 7: ...nto AC outlet Connect charger plug into 5 VDC jack 8 LED 9 indicates charging status as follows OFF AC not connected RED Charging battery GREEN Fully charged RED GREEN flashing Charging error Verify c...

Page 8: ...ors having either PC UPC or APC polished end faces A key on the probe snout combined with a slot on the adapter tips assures that adapter tips never loosen during use under any circumstances Quad slot...

Page 9: ...splayed in the top left of the Live Image screen to indicate the user s selection G H F D C B E Powering Up Down Enabling Optical Inspection Ports Power Up Press and release the Power key A Power Down...

Page 10: ...l 1 25 mm and 2 5 mm SC and LC in both UPC and APC polish types A slot on the adapter tip D combined with a key on a probe snout C eliminates loosening during normal use Installing Adapter Tips Align...

Page 11: ...der B on the FOCIS Duel display indicates the current focus level relative to focus range 4 Left arrow key In Live Image node toggles between Port 1 and Port 2 images 5 Right arrow key Press to autofo...

Page 12: ...arrow keys to manually adjust focus When the Auto Focus option is disabled G in the Setting screen and Capture key is pressed Image is captured without adjusting focus Image is analyzed if Pass Fail s...

Page 13: ...eft Right arrow keys 4 End face Image displays end face image with Pass Fail overlay if enabled 5 Back soft key press to return to previous screen 6 Image Layers soft key use Up Down keys to view imag...

Page 14: ...lay Tabs with the Pass Fail display tab selected 4 Analysis Rule applied to determine Pass Fail 5 Analysis Zones A core B cladding C adhesive D contact area 6 Scratch analysis results for each zone Re...

Page 15: ...tab selected 4 Results ID field indicates default folder file names Blue highlighted indicates that results are not saved 5 Time Date field indicates Time Date of the displayed captured image 6 Rule f...

Page 16: ...ce Info Use to view serial number software revision etc Press Select A or Right arrow key to display a sub screen of the selected menu item While in a sub screen press Up Down arrow keys to navigate a...

Page 17: ...e Cladding Shown below is the display when the IEC rule for single mode PC connector with return loss 45 dB is selected The table identifies the number of scratches or defects of a certain size which...

Page 18: ...Rule C Press Select or Right arrow key to display a list of the available Rules D Use Up Down arrow keys to highlight the desired Rule group E Press Select or Right arrow key to display a sub list F U...

Page 19: ...ired rule to edit Press the Right arrow key to view details screen for currently selected rule While in the Rule details screen D use arrow keys to highlight the desired Region and Scratches Defects p...

Page 20: ...enable on 2nd Capture key 4 Highlight and select Save to Folder File Use to select and edit the desired folder file field When Auto Send Save is enabled press Capture from Live Image mode to auto focu...

Page 21: ...tery life Highlight and select the Auto dim option F From the displayed sub menu G Select Auto dim use Left Right arrow keys to enable disable auto dimming Select Delay use Up Down arrow keys to incre...

Page 22: ...le End Cable Pair Mode Pair Type or Fiber Press Select or Right arrow key to display Editor B Use arrow keys to edit text field C Press Ok D soft key to save new name Note this will make the newly cre...

Page 23: ...before connector cleaned After image after connector cleaned Input Output Input network input connector image Output network output connector image Documenta tion As built image of connector when net...

Page 24: ...d display a list of existing files Use Up Down arrow keys to navigate and highlight the desired image File D Press Right arrow key to open the selected image File Press Back soft key or Capture key to...

Page 25: ...e displayed Device List screen select your smart device B Press Select Select Set Default Connection C Press Select Verify that FOCIS Duel indicates that it is paired with your smart device In Capture...

Page 26: ...ocus capture analyze and send image to FlexTester FlexScan On FlexTester After a few seconds captured image will appear on your FlexTester Press Right arrow key on FlexTester to view Pass Fail results...

Page 27: ...Duel internal memory Double click on RESULTS folder Drag copy or move some or all of the results to your PC When finished disconnect USB cable and turn off FOCIS Duel since FOCIS Duel will remain on a...

Page 28: ...www AFLglobal com or 800 321 5298 603 528 7780 Thank you for choosing AFL Test Inspection Test Inspection A FLTest Inspectio n...

Reviews: