Pos.
Life phases
Description of hazard
Risk
assessment
Measures to reduce risk
PL
7
Maintenance,
commissioning
Risks of limb crushing,
bruising and broken
bones due to accessing
the travel range of the
device when the
protective door is open.
S = S2
F = F2
O = O2
A = A1
Erg = 4
1.
The pressurised air
supply must be reliably
disconnected.
2.
The "safety relay" input
(X33) on the controller
C1xxx must be
deactivated or the
power pack (72 V) must
be reliably disconnected
from the power supply
on the primary side.
3.
The power pack (72 V)
must be reliably
disconnected from the
power on the primary
side when using the
B1100, E12xx or E1xxx
controllers.
4.
For linear motor axes
(excluding ES40, ES40-
HP, PDL40 and PDL40-
HP) through secure
monitoring of the
reduced speed!!!
Observe the special
documentation!!!
Furthermore, specialist
personnel must check
that all components
have been properly
installed and ensure
that there is no
manipulation.
S = S2
F = F1
P = P1
PL = c