Installation, assembly & setting
26 – 48
Assembly instructions EN
CS 6/20 - CS 6/40
Date 01.06.2021
Version 2.0
6.2.2 Tightening torques for screws
For assembling use screws with the following minimum specifications:
Standard
VDI 2230
Screw strength
Category 8.8
Surface:
Galvanized blue, oiled or greased
Thread
Tightening torque
M2
0.32 … 0.39 Nm
M2.5
0.65 … 0.81 Nm
M3
1.1 … 1.4 Nm
M4
2.6 … 3.3 Nm
M5
5.2 … 6.5 Nm
M6
9.0 … 11.3 Nm
M8
21.6 … 27.3 Nm
6.2.3 Connection to the pneumatic system
When connecting the compressed air supply for the first time, make sure that
all compressed air throttles are closed.
Vent the system slowly!
The minimum compressed air quality shall comply with the specifications of
ISO 8573-1:2010.
WARNING
Danger when connecting to pneumatics!
The pneumatic system can pose various hazards that can cause serious or
fatal injuries if the work is carried out improperly.
Only qualified personnel may work with or on the pneumatic system!
The required protective equipment shall be provided and used.
NOTICE
Functional impairment to leaking compressed air connections!
Unused air connections that are not hermetically sealed lead to a pressure
loss and thus to functional impairment.
Before installing the module in a system, all unused compressed air
connections must hermetically sealed.
Perform a leak test!
Summary of Contents for 50386049
Page 45: ...Assembly instructions EN CS 6 20 CS 6 40 Date 01 06 2021 Version 2 0 45 48 ...
Page 46: ...46 48 Assembly instructions EN CS 6 20 CS 6 40 Date 01 06 2021 Version 2 0 ...
Page 47: ...Assembly instructions EN CS 6 20 CS 6 40 Date 01 06 2021 Version 2 0 47 48 ...
Page 48: ...48 48 Assembly instructions EN CS 6 20 CS 6 40 Date 01 06 2021 Version 2 0 ...