Electrical Features of Connectors
DIGITAL MICROPHONE POD
Proprietary connector – use only with AETHRA microphone pod. Do not use in configurations other than those expressly
described.
LINE IN/OUT
RCA
Pin Connection:
Tip: Unbalanced signal
Jacket: Ground
Nominal Input/Output Level (RCA):
-14 dB (150 mV rms. standard LINE level)
Nominal Input Impedance (RCA):
Zout = 10 K
Ω
Nominal Output Impedance (RCA):
Zout = 100
Ω
Maximum Input Level (RCA):
+8 dB (2 V rms.)
Maximum Output Level (RCA):
+2,11 dB (1 V rms.)
Nominal Dynamic Range:
> 50 dB
88