Monitor
In this page is possible to configure system video outputs.
You can access three menus:
•
Settings
•
PIP-PaP
•
Plasma
Settings
In this page you can set following system parameters:
•
Monitors Number
•
Monitor Menu
•
Video outputs
Dropdown Menu ”
Monitors Number
” (default setting: Automatic).
Following table shows all available configurations:
Dropdown menu
“Monitors Number”
Connected monitors
Automatic
System automatically recognises connected
monitors
XGA
One XGA Monitor
TV1
One analogic monitor
TV1+TV2
Two analogic monitor
TV1+XGA
One analogic monitor
and one XGA monitor
TV1+ TV2+XGA
Two analogic monitor
and one XGA monitor.
Dropdown Menu ”
Monitor Menu
” (default setting: Automatic).
In case the Multi Monitor configuration has been choosen, so to have more monitors connected to the system, is possible to
choose where to see GUI – Graphical user interface.
Available configurations are:
Automatic
GUI set by the system
TV1
GUI always on TV1
TV2
GUI always on TV2
XGA
GUI always on XGA
16:9 check box (
use only with 16:9 monitors).
If selected system adds vertical side banners in order to scale fullscreen video image from 4:3 to 16:9.
16:9 selection is possible for both TV1, TV2 and XGA video outputs.
TV1:
connect a monitor or an analogic TV to TV1 video output (RCA connector, point
2
of cabling scheme).
16:9
check box (
use only with 16:9 monitors).
TV2:
connect a monitor or an analogic TV to TV2 video output (RCA connector, point
2
of cabling scheme).
16:9
check box (
use only with 16:9 monitors).
38