background image

8

Do not operate the Aerus

®

 Pure & Clean without the Filter Assembly and Back Cover properly installed.

WARNING

  

REPLACE ACTIVEPURE CELL

 

The CELL indicator will light up if the ActivePure

®

 Cell is no longer working. To order a new ActivePure Cell, contact your  

 

Independent Distributor/Contractor or Aerus Customer Service at 800.572.0502 (U.S.) or 800.668.0763 (CANADA).

 

NOTE:

  The ActivePure Cell should be replaced every one (1) year, even if the unit does not display this message.

 

When the CELL indicator starts flashing, you will need to perform the following operations to reset: 

• 

After 1 year of cumulative use, the CELL indicator starts flashing. After the user replaces the new ActivePure Cell according  

 

to the operation steps on page 10 of the manual, long press the RESET button for three seconds under the power off / standby  

 

state, you will hear a beep sound to let you know the reminder has been cleared. 

 

When the CELL indicator starts flashing in red, you will need to perform the following operations to reset: 

• 

The CELL indicator flashes in red to remind the user that ActivePure Cell is not properly installed. After disconnecting the  

 

power supply, reinstall ActivePure Cell and check whether the socket is installed properly. After the installation is  

 

successful, there is no need to press the RESET icon, the red light will automatically turn off. After the above operations,  

 

if the indicator remains flashing in red, ActivePure Cell is possibly damaged. In this case, contact your Independent Distributor/ 

 

Contractor or Aerus Customer Service at 800.572.0502 (U.S.) or 800.668.0763 (CANADA).

Resetting the Reminders 

The reminders you need to reset are the PERFORM CLEANING and REPLACE ACTIVEPURE CELL indicators (after performing maintenance, 
press the Reset icon and the screen will stop flashing to let you know the reminder has been cleared, please see above instructions for each 
indicator).

GENERAL MAINTENANCE

Unplug the unit before performing any maintenance procedures.

WARNING

Periodic maintenance is required to ensure that your Aerus Pure & Clean operates properly. The unit will display a PERFORM CLEANING 
reminder when it's time to perform regular maintenance. If you are operating your unit in a severely polluted environment, cleaning of the 
unit, ActivePure Cell, and Filter Assembly should be done more frequently. Shown here are basic procedures that should be carried out to 
keep your unit running at top performance. 

For optimal performance, and to prevent damage not covered by your warranty, install the Optional HEPA Filter. Failure to perform routine 
maintenance could adversely affect the proper function of the unit or cause it to fail prematurely.

NOTE:

  If a unit is returned for repair, and it is determined that neglect of the unit or unauthorized tampering with any mechanical or  

 

electronic component of the unit caused the failure, Aerus reserves the right to void the product warranty. This will require the  

 

owner to pay for any required repairs.

Cleaning the Case 

Wipe the unit with a soft cloth dampened (not wet) with water. Do not use chemicals or solvents. Vacuum the Top and Rear Grills periodically  
to remove any lint buildup.

MAINTENANCE REMINDERS (CONTINUED)

Summary of Contents for Pure & Clean A1040A

Page 1: ...x2 READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION PORTABLE AIR PURIFICATION SYSTEM ...

Page 2: ...orms to UL STD 867 Mechanical Nominal Airflow Rate 40 60 CFM Adjustable Speed Fan Sound Level 45 dB A on low 55 dB A on high Weight Dimensions 7 6 lbs 3 45 kg 11 75 H x 9 5 W x 10 D 29 8 cm x 24 1 cm x 25 4 cm Operating Temperature 34 F 100 F 1 6 C 38 C Recommended Maximum Coverage in a Contiguous Space1 Up to 2 000 sq ft 185m2 depending on occupant density and other factors1 High density commerci...

Page 3: ...rom outlet pull firmly on the plug DO NOT unplug by pulling on the cord Always unplug the unit before moving or cleaning or whenever the unit is not in use DO NOT use outdoors or on wet surfaces DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit doing so will void your warranty Connect to properly grounded outlets only To reduce the risk of electrical shock do n...

Page 4: ... this device DIRECTIONS FOR USE Plug the cord into a working electrical outlet leaving at least one inch of open area to allow for airflow Please see owner s manual for detailed instructions on using handling storing and disposing of the device and procedures to mitigate any associated risks The use of this device is a supplement to and not a substitute for standard infection control practices use...

Page 5: ...URES 1 Remove protective packaging 2 Remove unit from shipping carton 3 Remove all protective materials 4 Check for shipping damage and loose or broken parts 5 Read Owner s Manual thoroughly prior to installation 6 Determine placement location for the unit See Operation on page 5 7 Insert the Power Supply Plug into the power receptacle on the rear of the unit Plug the appropriate cord into the Pow...

Page 6: ...Push the A PURE A PURE x2 button twice to set it to A PURE x2 level which will be illuminated on the screen 6 Push the Fan button four times to reach the highest speed 5th level A PURE MODE The unit s display shows the fan speed low to high and A PURE to indicate that the ActivePure Cell and ionization are both functioning normally A PURE x2 MODE A PURE x2 lights up indicates that 2 ActivePure Cel...

Page 7: ...NG The perform cleaning CLEAN indicator will come on approximately 180 days for optimal performance it is recommended to perform cleaning on your unit every 180 days Clean the Filter Assembly See Page 8 Vacuum the ActivePure Cells Vacuum Top and Rear Grill openings NOTE Be sure to press the Reminder Reset icon to clear the reminder following regular maintenance see below When the CLEAN indicator s...

Page 8: ...t Distributor Contractor or Aerus Customer Service at 800 572 0502 U S or 800 668 0763 CANADA Resetting the Reminders The reminders you need to reset are the PERFORM CLEANING and REPLACE ACTIVEPURE CELL indicators after performing maintenance press the Reset icon and the screen will stop flashing to let you know the reminder has been cleared please see above instructions for each indicator GENERAL...

Page 9: ...ment filters see pages 8 9 for removal and installation instructions NOTE Filter Assembly life will vary based on the operating environment Changing the ActivePure Cell The ActivePure Cell should be replaced when REPLACE ACTIVEPURE CELL appears on the display or twelve 12 months when used continuously To change the ActivePure Cell follow the instructions on page 10 GENERAL MAINTENANCE CONTINUED RE...

Page 10: ...educe VOCs and other contaminants NOTE Removing the Optional HEPA Filter Sheet will increase the airflow of the unit UNINSTALLING THE OPTIONAL HEPA FILTER SHEET Unplug the unit before performing any maintenance procedures 1 Remove the Filter Assembly See Page 8 2 Remove the Optional HEPA Filter Sheet on top of the Prefilter 3 Replace the Filter Assembly inserting the bottom of the Filter Assembly ...

Page 11: ...bscrews 4 Slide the ActivePure Cell down and out of the unit INSTALLING THE ACTIVEPURE CELLS WARNING Unplug the unit before performing any maintenance procedures Do not operate the Aerus Pure Clean without the Filter Assembly and Back Cover properly installed 1 Slide the ActivePure Cell up and into the unit Be sure the back lip of the ActivePure Cell engages the two slotted protrusions at the rear...

Page 12: ...nt and the equipment appears unsuccessful Problem Lack of air movement improper placement of the unit Symptom Visual haze of smoke and or particulate remain within the environment Problem Lack of ionization and or air movement 4 Air flow is restricted or reduced Is the unit properly placed away from objects that may obstruct air flow Are the Filter Assembly Back Cover and Top and Rear Grill clean ...

Page 13: ...Pure Cell 50106 Filter Assembly 50107 Power Supply with U S Euro Plug 50108 To order replacement parts contact your Independent Distributor Contractor or Aerus Customer Service at 800 572 0502 U S or 800 668 0763 CANADA REPLACEMENT PARTS SERVICE ...

Page 14: ...rage prior to purchasing a product contact Aerus Customer Service at 800 572 0502 U S or 800 688 0763 CANADA with the serial number located on the back of the unit EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT AS PROVIDED HEREIN AND TO THE EXTENT CONSISTENT WITH APPLICABLE LAWS WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND ALL OTHER WARRANTIES OF ANY KIND EXPRESS OR IMPLIED ARE HEREBY EX...

Page 15: ...his equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television which can be determined by turning the equipme...

Page 16: ...this product please contact Customer Service 800 572 0502 U S 800 668 0763 CANADA www aerusonline com Aerus LLC 1300 Valley Drive Bristol VA 24201 800 572 0502 Aerus Canada Inc 3480 Laird Road Suite 2 5 Mississauga ON L5L 5Y4 800 668 0763 Aerus LLC All Rights Reserved ...

Reviews: