31
System using more or less salt
than regenerant setting.
a. Foreign matter in valve causing incorrect
flow rates.
a. Remove brine control and flush out
foreign matter. Advance control to brine/
slow rinse, to clean valve (after so doing
position control to "fast rinse” to remove
regenerant from tank).
Intermittent or irregular
regenerant draw.
a. Low water pressure.
b. Defective injector.
a. Set pump to maintain 20 psi at conditioner.
b. Replace injector. (Contact dealer)
No conditioned water after
regeneration.
a. No regenerant in regenerant tank.
b. Injector plugged.
c. Air check valve closes prematurely.
a. Add regenerant to regenerant tank.
b. Clean injector and screen.
c. Put control momentarily into brine/slow
rinse. Replace or repair air check if needed.
(Contact dealer)
Backwashes or purges at
excessively low or high rate.
a. Incorrect drain controller used.
b. Foreign matter affecting valve operation.
a. Replace with correct size controller.
(Contact dealer)
b. Remove drain controller and clean ball and
seat.
No water flow display when water
is flowing.
a. Bypass valve in bypass.
b. Meter probe disconnected or not fully
connected to meter housing.
c. Restricted meter turbine rotation due to
foreign material in meter.
a. Shift bypass valve to not-in-bypass
position.
b. Fully insert probe into meter housing.
c. Remove meter housing, free up turbine and
flush with clean water. Turbine should spin
freely. If not, replace meter. (Contact dealer)
Run out of conditioned water
between regenerations.
a. Improper regeneration.
b. Incorrect regenerant setting.
c. Incorrect hardness or capacity settings.
d. Water hardness has increased.
e. Restricted meter turbine rotation due to
foreign material in meter.
a. Repeat regeneration, making certain that
correct regenerant dosage is used.
b. Set P6 to proper level. See salt setting
chart.
c. Set to correct values. See Programming
section.
d. Set hardness to new value. See
Programming section.
e. Remove meter housing, free up turbine
and flush with clean water. Turbine should
spin freely; if not, replace meter. (Contact
dealer)
Regenerant tank overflow.
a. Regenerant valve disc 1 being held open
by foreign matter.
b. Valve disc 2 not closed during regenerant
draw causing brine refill.
c. Air leak in regenerant line to air check.
d. Improper drain control for injector.
e. Drain control clogged with resin or other
debris.
a. Manually operate valve stem to flush away
obstruction.
b. Flush out foreign matter holding disc open
by manually operating valve stem.
c. Check all connections in regenerant line for
leaks. Refer to instructions.
d. Too small of a drain control with a larger
injector will reduce draw rates.
e. Clean drain control.