Display Icons
Figure 19
Note:
In normal operation and during programming, only a few
of the icons will actually be displayed.
1. Days of the week. The flag immediately below the day
will appear when that day has been programmed as a
day the system should regenerate (used with 7-day timer
programming).
2. See #3
3. This cursor is displayed when the days between regeneration
are being programmed (used with .5 to 99 day regeneration
programming).
4. One of these cursors will be displayed to indicate which day
will be programmed into the controller.
5. "PM" indicates that the time displayed is between 12:00
noon and 12:00 midnight (there is no AM indicator). PM
indicator is not used if clock mode is set to 24-hour.
6. When "MIN" is displayed, the value entered is in minute
increments.
7. When "Kg" is displayed, the value entered is in kilograms or
kilograins.
8. Four digits used to display the time or program value. Also
used for error codes.
9. Colon flashes as part of the time display. Indicates normal
operation.
10. Locked/unlocked indicator. In Level I programming this is
displayed when the current parameter is locked-out. It is
also used in Level II programming to indicate if the displayed
parameter will be locked (icon will flash) when controller is in
Level I.
11. When "x2" is displayed, a second regeneration has been
called for.
12. The recycle sign is displayed (flashing) when a regeneration
at the next time of regeneration has been called for. Also
displayed (continuous) when in regeneration.
13. The display cursor is next to "SALT" when programming the
amount of regenerant. If the controller is on a 3-cycle filter
then backwash time is programmed.
14. The display cursor is next to "REGEN TIME & DAY" when
programming the time of regeneration and the days of
regeneration.
15. The display cursor is next to "TIME & DAY" when
programming the current time and day.
16. The hourglass is displayed when the motor is running. The
camshaft should be turning.
17. These cursors will appear next to the item that is currently
displayed.
18. X100 multiplier for large values.
19. Shows when water is flowing through the valve.
20. Used with #24, #25, and #26. Displays a sequence number
or a value.
21. History Values (H). The number displayed by #23 identifies
which history value is currently displayed.
22. Parameter (P). Displayed only in Level II Programming. The
number displayed by #23 identifies which parameter is
currently displayed.
23. Cycle (C). The number displayed by #23 is the current cycle in
the regeneration sequence.
24. Hardness setting—only used with 760 and 760C controllers.
25. Capacity display—shows estimated system capacity.
PM
MIN
KG
x2
Time & Day
Salt
SU MO TU WE TH FR SA
x100
P
H
C
Capacity
22
15
16
14
13
25
24
18
7
6
5
3
4
23
19 8
8
1
17
10
9
20
21
12
11
Regen Time & Day
Hardness
DAYS
Summary of Contents for Origins WC300
Page 1: ...Operation Manual 00947 1821 EA 03671...
Page 33: ...Manuel d utilisation 00947 1821 EA 03671 A D O U C I S S E U R D E AU WC300...
Page 66: ...66...
Page 67: ...67...