13
TROUBLESHOOTING
Under no circumstances should your Air Scrubber Mobile by Aerus
®
unit be operated while any
part of the case is damaged, missing, or disassembled. If the case is damaged, return your
unit to Aerus for repair or replacement. Direct exposure to the internal UV light may cause eye
damage.
WARNING
Troubleshooting — What To Look For First
1.
Unit does not operate/the O
3
Boost does not operate/all LEDs off
•
Unplug and reinsert the adapter plug and adapter to check where the power supply is plugged in to be sure it
has power.
•
If using the 12 Volt DC car adapter, remove the fuse by unscrewing the end of the adapter and check to see if it is blown.
Replace it with the same type and rating fuse only (See Specifications on page 2). If the fuse is not blown, check the outlet
for proper voltage.
2.
UV bulb or O
3
Boost may not be working
•
Press the PURIFIER UP or PURIFIER DOWN buttons to turn the Purifier function ON.
•
If checking O
3
Boost operation, press the O
3
Boost UP button to turn the O
3
Boost ON
•
Remove the Bulb Assembly, clean, and reinstall (see diagram on Page 4).
•
If cleaning and reinstalling does not correct the problem, replace the Bulb Assembly (service kit #9950209).
•
When looking through the rear inlet vents in low light you should see a slight bluish glow. If there is no glow, replace the
Bulb Assembly (service kit #9950209).
3.
L
ack of air flow
:
•
Make sure the intake vents are not blocked and the front of the unit is clear.
•
Check to see if the fan is operating (if not, see above).
If your unit fails to operate properly after performing troubleshooting, contact your Independent
HVAC Contractor for further assistance. You may also contact Customer Service at 866.736.0503,