english
connection
exhaUSt conveyoR line
All of the central power units have a dual air exhaust
outlet to permit the installation of the air exhaust
line on both sides of the central power unit, making
installation easier.
Select the most convenient air exhaust outlet to connect
the central power unit. Connect the exhaust conveyor
line hose with the provided clamp (f).
It is recommended to install an exhaust hose that is no
longer than 5 metres.
If the exhaust line is longer, use a hose with a diameter
of ø 63 or larger and install a silencer of a suitable
diameter.
Always position the silencer near the exhaust grille.
Air exhaust line components
1 - silencer ø100
2 - conical increase ø50F - ø82F
3 - exhaust grille ø82
4 - outlet hole ø82
Use an exhaust grille code Tr310 or similar grille without
the presence of insect protection netting.
In the instance of a ø50 terminal, use an exhaust grille
code Tr316.
Dust inlet line connection
All of the central power units have a dual dust inlet to
permit the connection of the socket line hose on both
sides of the central power unit, making installation
easier.
Select the most convenient central power unit dust
inlet to connect the dust inlet line. Assemble the rubber
sleeve (a) on the dust inlet using the two provided
clamps (b) and connect it to the inlet hose (c).
Close the dust inlet not in use
The dust inlet not in use (d) must be closed by pressing
on the relevant closing cap (e) provided.
connection
dUSt inlet line
OK
mbar
OK
mbar
c
d
b
a
d
b
c
a
e
d
NOTE
ø 50
ø100
300 mm
ø 50
ø 82
ø 82
1
3
2
4
OK
mbar
max 5m.
f
g
Installation
Installation
13