ECO165LM Hardware Manual
Electrical Specifications and Installation
3.3. Motor and Feedback Specifications
Table 3-5:
Feedback Specifications
Encoder Specifications
Supply Voltage
5 V ±10%
Supply Current
250 mA
Output Signals
Sinusoidal Type (Incremental Encoder)
: 1 V
pk-pk
into 120 Ω Load (differential
signals SIN+, SIN-, COS+, COS- are .5 V
pk-pk
relative to ground.)
Digital Output (Incremental Encoder)
: RS422/485 compatible
Limit Switch Specifications
Supply Voltage
5 V
Supply Current
25 mA
Output Type
Open Collector
Output Voltage
5 V
Output Current
10 mA (sinking)
Output Polarity
Normally Closed (NC)
l
Sinks current to ground (Logic "0") when not in limit
l
High impedance (Logic "1") when in limit
l
Requires external pull-up to +5 V (10 kΩ recommended)
Notes:
l
If the ECO165LM is driven beyond the electrical limit, it will encounter a mechanical stop. Impacting the mechanical stop could
cause damage to the stage even at low speeds.
www.aerotech.com
Chapter 3
33