Electrical Specifications and Installation
ECO165LM Hardware Manual
1
A1
A2
A3
A4
3
11
20
10
5
21
17
16
2
14
15
13
18
7
6
25
Typical Aerotech
Vertical or Rotary Axis Stage
HALL B
HALL C
COM
COM
+5V
+5V
THERM
COSINE
COSINE-N
SINE
SINE-N
MARKER
MARKER-N
BRAKE+
BRAKE-
CASE
CASE
SAFE
SWITCH
MOVE
HALL A
26 AWG
16 AWG
16 AWG
16 AWG
16 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
26 AWG
MOTOR
CONNECTIONS
THIRD PARTY CONTROLLER
12
24
+LIMIT
-LIMIT
1
+t°
+
-
+5V
10K
(typ)
10K
(typ)
10K
(typ)
+5V
10K
Pull-Up
10K
Pull-Up
Pull-Up
1K
+5V
+5V
120 Ω
120 Ω
120 Ω
Figure 3-3:
Motor and Feedback Wiring for a Typical Vertical or Rotary Axis Stage
32
Chapter 3
www.aerotech.com