DR500 Operation and Technical Manual
Set Up
Version 1.6
Aerotech, Inc.
2-27
Table 2-18.
AS3005 Series Electrical Specifications
Units
AS3005
Peak Current Output (2 sec)
Amps
5
Continuous Output Current
Amps
*
Output Fuse, F1 (3 AG, slow blow)
Amps
*
Peak Output Voltage
Volts
30
Power Amplifier
Gain (continuous output)
Amps/Volt
.5
Shutdown Input
Removes Input Command
Minimum Load
ohms
4
Operating Temperature
°C
0 to 50
Storage Temperature
°C
-30 to 85
Weight kg
(lb)
0.5
(1)
* Load dependent, consult factory.
Table 2-19.
AS3005 Series Test Points
Test Point
Signal
TP5
Phase C Current Feedback
TP8
Phase B Current Feedback
TP10
Phase A Current Feedback
TP12
Torque Command (Phase A)
TP6
Phase C Current Command
TP9
Phase B Current Command
TP11
Phase A Current Command
TP7
Torque Command (Phase B)
DS1
L.E.D. Drive Enable
TP4 Common
TP3 -12V
TP2 +12V
P2
Phase B Offset Adjust
P3
Phase A Offset Adjust
P4
Phase C Offset Adjust
2.2.9. Internal System Wiring
The DR500 wiring varies depending upon the desired AC input voltage, the number of
axes, and the desired DC bus voltage required for the drive modules. A system wiring
drawing is provided with the documentation package for all DR500 systems.