OIP-AC01 Quick Installation Guide

 

 

1. PACKAGE

 

CONTENTS

 

6U Rack Chassis 

Installation Guide 

Power Adapter 

 

 

 

Power Connector 

M5 Screw x8 

Cable Clip x5 

 

(

Appearance may vary 

depending on country/region

 

 

 

 
 
 

2. Power & System Requirements 

 Power Requirement: DC 12V, 3A power supply for the cooling fan system. 

 System Requirement: 

  The 6U rack chassis requires a minimum of 266.7mm (10.5in) contiguous 

free space in the rack for mounting. 

  With the Cooling Fan System installed, an additional 1U space above the 

chassis should be left empty to provide space for air to flow freely. 

 

 

3. Installation Instructions   

STEP 1 

Install the OIP-AC01 to the rack with M5 Screws*8pcs. 

 

 

STEP 2 

Unscrew the 3 thumbscrews holding the top locking panel in place, and remove 

the panel from the front of the chassis. Unscrew the 3 thumbscrews holding the 

bottom locking panel in place, and remove the panel from the front of the 

chassis.   

 

Note: The thumbscrews are connected to the locking panels with a retention mechanism 
and will not come completely free when they have been unscrewed from the chassis.

 

 