background image

BA10/20/30

 

Series User’s Manual 

Installation and Operation 

Version 1.6 

Aerotech, Inc.

 

  2-5 

 

Figure 2-2. 

Wiring to Minimize EMI and Capacitive Coupling 

2.3.2.  Fusing and Inrush Limiting  

The BA series amplifier does not contain a fuse or any inrush limiting internally.  These 
can be added externally to the AC input as shown in the figure below: 

Figure 2-3. 

Fusing and Inrush Limiting 

 

BA 

 

AMPLIFIER

 

GROUNDING 

 

SCREW

 

EARTH GROUND

 

CASE GROUND

 

MOTOR

 

TWISTED TOGETHER

 

SHIELD

 

One toroid (ferrite) around the three motor leads (two 

 

leads for brush motors). There should be 10 turns for 16 

 

AWG wire and 7 tunrs for 14 AWG wire. Use a Ferrox 

 

cube 500T600-3C81 core or equal.

 

This configuration is especially important if the BA amplifier is operating at DC bus voltages of 160 VDC or 320 VDC (e.g., 115 VAC or 230 VAC input power).

 

  LO

 

HI

 

A

 

B

 

C

 

 

BA SERIES

 

THERMISTOR AND FUSING

 

A.C.

 

Input

 

/2

 

+,

 

BLU

 

BRN

 

G/YEL

 

FUSE

 

DUE TO CAPACITIVE NATURE OF AMPLIFIER INPUT CIRCUIT, 
CURRENT INRUSH LIMITING IS RECOMMENDED. NEGATIVE 
TEMPERATURE COEFFICIENT THERMISTORS ARE USED FOR 
THIS PURPOSE. THERMISTOR IS TO BE PLACED IN THE AC HI 
LINE. ONLY ONE THERMISTOR NEEDED FOR ONE AMP. 
ALTERNATELY, 2 THERMISTORS CAN BE USED IN AC HI & LO 
FOR MULTIPLE AMPS IN PARALLEL.

 

RECOMMENDED MODELS:

 

     RODAN SURGE GIARD SG100 (20A RMS)

 

     AMETHERM #SL32IRO30 (30A RMS)

 

RECOMMENDED FUSE VALUES:

 

BA10                 10 ASB

 

    BA20

 

    BA30

 

  20 ASB

 

Summary of Contents for BA10 SERIES

Page 1: ...10 20 30 SERIES USER S MANUAL P N EDA121 V1 6 AEROTECH Inc 101 Zeta Drive Pittsburgh PA 15238 2897 USA Phone 412 963 7470 Fax 412 963 7459 Product Service 412 967 6440 412 967 6870 Fax www aerotech co...

Page 2: ...ite is continually updated with new product information free downloadable software and special pricing on selected products The BA Series User s Manual Revision History Rev 1 0a February 21 1995 Rev 1...

Page 3: ...1 40 Volt Option 2 6 2 3 3 Minimizing 50 60 HZ Line Interference 2 7 2 4 Integrated Configurations 2 9 2 4 1 Velocity Command Configuration 2 9 2 4 2 Current Command Configuration 2 10 2 4 3 Dual Phas...

Page 4: ...Table of Contents BA10 20 30 Series User s Manual iv Aerotech Inc Version 1 6...

Page 5: ...Option 2 6 Figure 2 5 Back propagation Line Filter Connection 2 7 Figure 2 6 Isolation Transformer Connection eliminates torque disturbance 2 8 Figure 2 7 Velocity Command Configuration 2 9 Figure 2...

Page 6: ...List of Figures BA10 20 30 Series User s Manual vi Aerotech Inc Version 1 6...

Page 7: ...Models and Voltage Configurations 1 2 Table 1 2 DIP Switch Functions 1 5 Table 1 3 Potentiometer Functions 1 6 Table 1 4 Connector P1 Pinouts 1 7 Table 2 1 Jumper Selections 2 2 Table 3 1 Ordering Inf...

Page 8: ...List of Tables BA10 20 30 Series User s Manual viii Aerotech Inc Version 1 6...

Page 9: ...ctober 19 1995 The report number is WLL 2956F The brushless amplifier was tested with a brushless servomotor To ensure that the product passes the conducted emissions tests a line filter and common mo...

Page 10: ...Regulatory Information BA10 20 30 Series User s Manual x Aerotech Inc Version 1 6...

Page 11: ...rushless servomotors The amplifiers are available in 3 peak output current ratings of 10 20 and 30 amps The BA amplifier package is a complete modular unit that includes heat sink metal cover and bus...

Page 12: ...s but it is recommended that this heat sink be mounted to a larger thermally conductive surface for further heat dissipation Complete electrical isolation is provided between the control stage and the...

Page 13: ...er is required to operate below 80 VDC The shunt regulator is not included with the BA10 20 drive 115 230 VAC AC1 AC HI AC2 AC LO EARTH GND ICMDA ICMDB ICMD Mon INPUT INPUT TACH HALL A HALL B HALL C S...

Page 14: ...ions Figure 1 3 Amplifier Hardware 1 4 1 Motor and AC Power Connections The three phase motor terminal connections are made at connections A B and C This area is designated as such on the amplifier In...

Page 15: ...losed Icont is 14 of Ipeak Continuous Current Peak 8 closed Icont is 27 of Ipeak Test 9 closed Closing this position allows the BALance potentiometer to manually control motor velocity or torque witho...

Page 16: ...set for velocity control using an external DC tachometer or incremental encoder for velocity feedback Refer to Table 1 3 for pot functions Table 1 3 Potentiometer Functions Potentiometer CW CCW Funct...

Page 17: ...input input Non inverting input of differential input circuit A positive voltage on this input causes CCW motor rotation torque or velocity mode For single ended operation connect command to this inpu...

Page 18: ...ositive voltage on this input causes CW motor rotation torque or velocity mode For single ended command operation ground this connection and connect signal to Pin 8 of P1 Pin 22 input icmdb Current co...

Page 19: ...uitry The following shows the internal circuitry for the BA amplifier Note that all of the logic inputs can tolerate 24VDC Figure 1 4 Fault Output Figure 1 5 Enable Shutdown Inputs FAULT OUTPUT 5 1K C...

Page 20: ...10K 1 10K 1 P1 11 74HC14 1UF ILMT 5V 10K 1 10K 1 P1 24 74HC14 1UF 5V 10K 1 P1 4 74HC14 R224 P1 16 P1 17 P1 18 P1 19 P1 5 P1 6 HEA HEB HEC SIN SIN N COS COS N 5V 5V 10K 1 10K 1 R225 R226 10K 1 R229 10K...

Page 21: ...r is decoupled from the mechanical system and no harm to personnel will result if the motor begins to spin Before performing the following steps ensure that the motor is completely disconnected from t...

Page 22: ...Introduction BA10 20 30 Series User s Manual 1 12 Aerotech Inc Version 1 6...

Page 23: ...hardware configurations using the switches jumpers connectors and power hook ups when used with a brush or brushless DC motor Also covered is wiring grounding and shielding techniques an explanation o...

Page 24: ...movement default JP10 2 3 Active high ILMT Logic high 5V on P1 24 stops CCW motor movement 1 2 Power stage drive signal phase A is derived from differential pre amp input BA drive performs self commut...

Page 25: ...d optional on BA10 BA20 JP3 JP4 JP5 JP6 T1 JP2 1 1 1 1 P3 1 6 7 14 Shunt Fuse 250 VAC 2 amp slow blow Side View of Shunt Sh RCN1 1 JP8 1 1 1 1 1 JP9 JP10 JP22 JP15 P1 1 1 1 1 JP25 JP13 JP11 JP12 JP26...

Page 26: ...hock hazard Additional electro static coupling exists between the three twisted motor leads and the foil shield of the motor cable This coupling forces high frequency currents to flow through the retu...

Page 27: ...AWG wire and 7 tunrs for 14 AWG wire Use a Ferrox cube 500T600 3C81 core or equal This configuration is especially important if the BA amplifier is operating at DC bus voltages of 160 VDC or 320 VDC e...

Page 28: ...r supply of the BA amplifier requires a minimum of 56 VAC input to operate properly The figure below shows the connection to the separate AC power board The connection is made to the AC input board wi...

Page 29: ...HI LO AC input power Since LO is referenced to earth ground back at the source the DC bus of the amplifier swings at 50 60 Hz with respect to the motor frame The path of current caused by this couplin...

Page 30: ...ce BA AMPLIFIER GROUNDING SCREW EARTH GROUND FRAME GROUND This configuration is especially important if the BA amplifier is operating at DC bus voltages of 160 VDC or 320 VDC e g 115 VAC or 230 VAC in...

Page 31: ...er closes and controls the velocity loop The velocity command configuration is shown in Figure 2 7 This configuration can drive both brush and brushless DC motors Figure 2 7 Velocity Command Configura...

Page 32: ...t Command Configuration Signals to Optional Position Loop Controller 3 Hall A B C 2 MKR MKR N 2 COS COS N 2 SIN SIN N 2 5V SIG COM MKR MKR N SIN SIN N COS COS N 5V SIG COM HALL A B C Square Wave Quadr...

Page 33: ...in Figure 2 9 The advantage to this configuration is that it provides the smoothest possible motion Figure 2 9 Dual Phase Command Configuration Signals to Position Velocity Commutation Loop Controller...

Page 34: ...10 volts for full current output Balance and Tach have no effect JP14 set to 2 3 default JP11 and JP13 set to 1 2 default JP3 JP5 JP15 and JP6 set to 1 2 default for brushless motor operation or 2 3...

Page 35: ...mmand Signal Adjustment Portion of the Pre Amplifier Circuit To minimize the possibility of electrical shock and bodily injury ensure that the motor is decoupled from the mechanical system to avoid pe...

Page 36: ...ss is unattainable the components connected to personality module RCN1 pins 8 9 and 7 10 may be need to be changed The BALance pot is used to cancel any bias in the internal or external control circui...

Page 37: ...11 illustrates the generated output voltage of the amplifier relative to the input Hall sequences The equipment needed for this test is a two channel oscilloscope and three resistors typically 10 Kohm...

Page 38: ...ure 2 11 Motor Phasing Motor Amplifier PHASE A PHASE B PHASE C Motor Rotation CCW 0 101 100 110 010 011 001 30 001 101 100 110 010 011 001 DEGREES COMMUTATION SEQUENCE HALL A B C 0 Commutation Wavefor...

Page 39: ...one for each phase of the DC brushless motor for DC brush motors only Phase A regulator is used Regulators A and B are each provided with a current command from either the internal six step commutatio...

Page 40: ...r DC brushless motor operation the signal at this pin would represent motor phase A current For DC brush motor operation this signal would represent the current flowing in the motor armature 10 volts...

Page 41: ...d use TV0 3 56 160 160 VDC bus 100 115 VAC input direct line operation 320 320 VDC bus 230 VAC input direct line operation includes shunt regulator Options S Shunt regulator Example BA30 320 S 15 A co...

Page 42: ...eg C 0 to 50 Storage Temperature deg C 30 to 85 Weight lb kg 2 5 1 1 Modes of Operation jumper selectable Brushless single current command with on board 6 step commutation from HED inputs dual phase c...

Page 43: ...tion CW motor shaft rotation is inhibited When ILMT is pulled to its active state motion in the negative direction CCW motor shaft rotation is inhibited TTL level input 0 to 5 VDC internal pull up 10K...

Page 44: ...velocity feedback input Input adjusts gain of command input DIP Switches Peak current limit 4 switches allow the user to set the peak current from 6 100 of max value RMS current limit 4 switches allo...

Page 45: ...nk must be flat to allow good thermal conductivity between the heat sink and the amplifier 5 If possible add a thermal conductivity enhancer i e thermal grease between the heat sink and the amplifier...

Page 46: ...etter heat dissipation Refer to Figure 3 3 Figure 3 3 Preferred Mounting of BA Amplifiers 82 0 3 23 TYP 119 9 4 72 TYP 2 FT 1FT 186 7 7 35 12 7 0 50 TYP 168 0 6 61 114 3 4 50 6 4 0 25 Typ CE 13 CONTRO...

Page 47: ...lows the generation of 56 VAC from a 115 VAC and 230 VAC source respectively When rectified by the BA amplifier 56 VAC yields an 80 VDC power bus The TV0 3 28 power transformer is an optional accessor...

Page 48: ...Technical Details BA10 20 30 Series User s Manual 3 8 Aerotech Inc Version 1 6...

Page 49: ...is disconnected from amplifier Resistance should read infinity 4 Shutdown P1 10 is not at active state for running amplifier 5 If amplifier faults remove AC for 30 seconds Brushless motor will not spi...

Page 50: ...Troubleshooting BA10 20 30 Series User s Manual 4 2 Aerotech Inc Version 1 6...

Page 51: ...motor DIP switch Dual In line Package switch A set of tiny toggle switches built into a housing commonly used on printed circuit boards Hall effect devices A set of three electro optical or magnetic...

Page 52: ...Glossary of Terms BA10 20 30 Series User s Manual A 2 Aerotech Inc Version 1 6...

Page 53: ...y covers defects in workmanship and material and is voided for all laser power supplies plasma tubes and laser systems subject to electrical or physical abuse tampering such as opening the housing or...

Page 54: ...lowing policy applies Aerotech will provide an on site field service representative in a reasonable amount of time provided that the customer issues a valid purchase order to Aerotech covering all tra...

Page 55: ...CCW LMT N HOME LMT N LMT COM LMT 5V 22 G YEL SPLICE P1 6 5 19 18 14 2 4 16 17 15 20 1 1 FT 24 GRY 24 VIO 24 W GRY 24 W BRN 24 W ORN 24 W RED 24 W GRN 24 W YEL 22 W BLK 22 YEL 24 R GRN 24 R YEL 24 W BL...

Page 56: ...NGUE EIK399 KEEP WIRE SHORT AS POSSIBLE 1 1 4 STRIP BACK INSULATION 3 16 FROM THIS END COVER ALL SOLDER CONNECTIONS WITH HEATSHRINK HEATSHRINK SECURED WITH CABLE TIE EIZ100 CABLE ECX566 START WITH 17...

Page 57: ...EMI interference 2 4 ENABLE LED 1 6 Encoder 2 9 Encoders 1 2 External Controller 2 9 F Fault conditions 1 2 feedback signals 1 2 Field Service Policy B 1 G GAIN pot 1 6 Grounding techniques 2 4 H Hal...

Page 58: ...1 11 Product Overview 1 1 PWM A 1 R RMS A 1 S Safety Procedures 1 11 Self Commutation 2 11 Shielding techniques 2 4 T TACH pot 1 6 Tachometer 2 9 Test 1 5 Torque command mode 2 12 Troubleshooting 4 1...

Page 59: ...ion regarding the latest changes to this manual Extensive changes if made may not be itemized instead the section or chapter will be listed with extensive changes in the corresponding General Informat...

Page 60: ...Revision History BA10 20 30 Series User s Manual R 2 Aerotech Inc Version 1 6...

Page 61: ..._________________________________________________ _____________________________________________________________________ _____________________________________________________________________ __________...

Page 62: ......

Reviews: