background image

For Devices Running HiveManager NG:

1. Power on the AP and allow it to find and connect to HiveManager NG. Once the AP

 

is connected

it appears in the table of devices on the 

Monitor > Devices

 page.

2. Select the check box next to the AP, and then choose 

Assign Country Code

 from the 

Actions

 drop-

down list. In the dialog box that appears, select the appropriate country from the drop-down list,
and then click 

Save

.

3. Upload your changes to the device.

Regulatory Compliance Statements

The regulatory compliance statements in this section apply to AP122 devices.

For Japan, the AP122 is restricted for indoor use in the 5150-5350 MHz band only.

Compliance Statements

The following compliance information applies to the AP122.

 

R&TTE Directive

This device is compliant with the following directives:

• R&TTE

 

Directive 1995/5/EC

AP122 Compliance Statement - Europe

EU Declaration of Conformity

This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The 

following test methods have been applied in order to prove presumption of conformity with the 
essential requirements of the R&TTE Directive 1999/5/EC:

IEC 60950-1:2005 +A1 +A2

Safety of Information Technology Equipment

EN 50385: / Article 3(1)(a) and Article 2 /EC)

Assessment of electronic and electrical equipment related to human exposure restrictions for 

electromagnetic fields (0 Hz-300 GHz)

EN 300 328 V1.9.1: 

Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband transmission 
systems; Data transmission equipment operating using wide band modulation techniques; 

Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

EN 301 893 V1.8.1: 

Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Harmonized EN 
covering the essential requirements of article 3.2 of the R&TTE Directive

Page 2 of 14

AP122 Hardware User Guide

11/14/2016

Summary of Contents for AP122

Page 1: ...n it is important to set the country code to the country in which the AP will be deployed to meet regulatory requirements and for optimal wireless operation To do this follow these steps The country c...

Page 2: ...nce Statement Europe EU Declaration of Conformity This device complies with the essential requirements of the R TTE Directive 1999 5 EC The following test methods have been applied in order to prove p...

Page 3: ...99 5 EC Espa ol Spanish Por medio de la presente Aerohive declara que el AP130 cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE...

Page 4: ...er Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or...

Page 5: ...operation as appropriate and iv Users should also be advised that high power radars are allocated as primary users i e priority users of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars...

Page 6: ...equipment complies with ISED RSS 102 radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm 7 8 between the ra...

Page 7: ...nt This icon indicates an electrical caution Failure to comply with an electrical notification can result in serious injury or death and extensive damage to equipment This icon indicates a laser cauti...

Page 8: ...e supervised to ensure that they do not play with the devices Electrostatic discharge ESD can damage equipment and impair electrical circuitry ESD damage occurs when electronic components are improper...

Page 9: ...the AP122 on a wall or other flat surface perform the following steps 1 Make two marks where you want to mount the device on the wall or surface exactly 2 5 64 cm apart 1 Drill two holes that are sli...

Page 10: ...er and to the network 1 Connect a standard RJ45 Ethernet cable from ETH0 on the AP to a switch 2 If the switch provides PoE power over Ethernet cabling the AP to the switch will power on the AP in a f...

Page 11: ...ightness bright soft dim off You can adjust the brightness level from bright the default to soft to dim or turn it off completely in HiveManager NG Navigate to Configure Network Policy Additional Sett...

Page 12: ...NJ 20W EU AH ACC INJ 20W US AH ACC INJ 20W AU AH ACC INJ 20W IL Reset Button Use the Reset button to reset the device or restore the factory default settings Insert a paper clip or similar tool into t...

Page 13: ...ating frequency Orthogonal Frequency Division Multiplexing OFDM modulation Rates Mbps 54 48 36 24 12 9 6 with auto fallback 802 11n 2 4 2 5 and 5 150 5 850 GHz operating frequency 802 11n modulation R...

Page 14: ...tions PoE nominal input voltages 48 V Typical PoE power consumption is 11 W RJ45 power input pins Wires 4 5 7 8 or 1 2 3 and 6 Environmental Specifications Operating temperature 32 to 104 F 0 to 40 C...

Reviews: