background image

HF-LPB100 Low Power Wi-Fi Module User Manual 

Shanghai High-Flying Electronics Technology Co., Ltd(www.hi-flying.com) 

- 1 - 

                               HF-LPB100  

Low Power Wi-Fi Module User Manual 

V 1.9 

 

Overview of Characteristic 

 

Support IEEE802.11b/g/n Wireless Standards 

 

Based on Self-developed High Cost Effective MCU 

 

Ultra-Low-Power for Battery Applications with Excellent Power Save Scheme 

 

Support UART/SPI/PWM/GPIO Data Communication Interface 

 

Support Work As STA/AP/AP+STA Mode 

 

Support Smart Link Function (APP program provide) 

 

Support Wireless and Remote Firmware Upgrade Function 

 

Support WPS Function 

 

Support Multi-TCP Link (5 Channel) Apllication 

 

Support Internal/External(I-PEX/SMA) Antenna Option 

 

3.3V Power Supply 

 

Smallest Size: 23.1mm x 32.8mm x (3.45

±

0.3)mm  

 

FCC/CE/TELEC Certificated 

Summary of Contents for HF-LPB100

Page 1: ... MCU Ultra Low Power for Battery Applications with Excellent Power Save Scheme Support UART SPI PWM GPIO Data Communication Interface Support Work As STA AP AP STA Mode Support Smart Link Function APP program provide Support Wireless and Remote Firmware Upgrade Function Support WPS Function Support Multi TCP Link 5 Channel Apllication Support Internal External I PEX SMA Antenna Option Single 3 3V ...

Page 2: ...ication 18 1 3 1 Hardware Typical Application 18 2 FUNCTIONAL DESCRIPTION 20 2 1 Wireless Networking 20 2 1 1 Basic Wireless Network Based On AP Infrastructure 20 2 1 2 Wireless Network Based On AP STA 20 2 2 Work Mode Transparent Transmission Mode 21 2 3 UART Frame Scheme 22 2 3 1 UART Free Frame 22 2 3 2 UART Auto Frame 22 2 4 Encryption 23 2 5 Parameters Configuration 23 2 6 Firmware Update 23 ...

Page 3: ... Port Application 35 4 AT INSTRUCTION INTRODUCTION 36 4 1 Configuration Mode 36 4 1 1 Switch to Configuration Mode 36 4 2 AT Instruction Set Overview 37 4 2 1 Instruction Syntax Format 37 4 2 2 AT Instruction Set 38 4 2 2 1 AT E 40 4 2 2 2 AT WMODE 40 4 2 2 3 AT ENTM 41 4 2 2 4 AT TMODE 41 4 2 2 5 AT MID 41 4 2 2 6 AT VER 42 4 2 2 7 AT LVER 42 4 2 2 8 AT FWSZ 42 4 2 2 9 AT RELD 42 4 2 2 10 AT FCLR...

Page 4: ...AT WSDNS 52 4 2 2 41 AT LANN 52 4 2 2 42 AT WAP 52 4 2 2 43 AT WAKEY 53 4 2 2 44 AT WAMAC 53 4 2 2 45 AT WADHCP 53 4 2 2 46 AT WADMN 54 4 2 2 47 AT WALK 54 4 2 2 48 AT WALKIND 54 4 2 2 49 AT PLANG 54 4 2 2 50 AT UPURL 55 4 2 2 51 AT UPFILE 55 4 2 2 52 AT LOGSW 55 4 2 2 53 AT LOGPORT 56 4 2 2 54 AT UPST 56 4 2 2 55 AT WEBU 56 4 2 2 56 AT MSLP 57 4 2 2 57 AT NTPRF 57 4 2 2 58 AT NTPEN 57 4 2 2 59 AT...

Page 5: ...ORK COMMANDS 66 B 1 Network Command 66 B 2 Hexadecimal Network Command 69 APPENDIX C HTTP PROTOCOL TRANSFER 72 C 1 HTTP AT command 72 C 1 1 AT HTTPURL 72 C 1 2 AT HTTPTP 72 C 1 3 AT HTTPPH 72 C 1 4 AT HTTPCN 73 C 1 5 AT HTTPUA 73 C 1 6 AT HTTPDT 73 C 2 HTTP Example 73 C 3 Sending HTTP Raw Data in Throughput Mode Recommend 74 C 4 Sending HTTP Request By AT Command 75 APPENDIX D REFERENCES 77 D 1 Hi...

Page 6: ... Figure 14 System Web Page 27 Figure 15 Work Mode Page 27 Figure 16 STA Setting Page 28 Figure 17 AP Setting Page 28 Figure 18 Other Setting Page 29 Figure 19 Account Page 29 Figure 20 Upgrade SW page 30 Figure 21 Restart Page 30 Figure 22 Restore Page 31 Figure 23 Internal Webpage 31 Figure 24 STA Interface Debug Connection 32 Figure 25 AP Interface Debug Connection 32 Figure 26 CommTools Serial ...

Page 7: ... Specifications 10 Table 2 HF LPB100 Pins Definition 11 Table 3 HF LPB100 External Antenna Parameters 15 Table 4 HF LPB100 Evaluation Kit Interface Description 16 Table 7 HF LPB100 GPIO PWM Pin Mapping Table 24 Table 8 HF LPB100 Web Access Default Setting 26 Table 9 Error Code Describtion 38 Table 10 AT Instruction Set List 38 Table 11 Reflow Soldering Parameter 63 ...

Page 8: ...T command add AT SMTLK AT LPTIO Ed V1 51 01 22 2014 Update Shipping information Ed V1 6 05 10 2014 Update GPIO description Update SDK download Add AT UDPLCPT AT NTPSER command Update Shipping information Ed V1 7 09 25 2014 Correct module height size Add AT WIFI AT SMEM command Modify AT RECV command Modify AT UARTTE AT TCPTOB AT FWSZ command description Delete AT UDPLCPT AT CFGWR AT CFGFR AT CFGRD...

Page 9: ...sonal medical application and industrial control that have lower data rates and transmit or receive data on an infrequent basis The HF LPB100 integrates all Wi Fi functionality into a low profile 23 1x32 8x 2 7mm SMT module package that can be easily mounted on main PCB with application specific circuits Also module provides built in antenna external antenna option 1 1 1 Device Features Single str...

Page 10: ...n board PCB antenna Hardware Parameters Data Interface UART SPI PWM GPIO Operating Voltage 2 8 3 6V Operating Current Peak Continuous TX 300mA Normal WiFi ON OFF DTIM 100ms Average 12mA Peak 300mA Operating Temp 40 85 Storage Temp 45 125 Dimensions and Size 23 1mm 32 8mm 3 45 0 3 mm Software Parameters Network Type STA AP STA AP Security Mechanisms WEP WPA PSK WPA2 PSK Encryption WEP64 WEP128 TKIP...

Page 11: ... 1 Pins Definition Figure 2 HF LPB100 Pins Map Table 2 HF LPB100 Pins Definition Pin Describtion Net Name Signal Type Comments 1 17 32 48 Ground GND Power 2 Debug Pin SWCLK I PD Debug functional pin No connect if not use 3 NC 4 NC 5 Debug Pin SWD I O PU 6 N C No connect 7 GPIO AD Sleep_RQ I PU GPIO7 No connect if not use 8 GPIO AD Sleep_ON O GPIO8 No connect if not use ...

Page 12: ... PU Leave it no connect 26 N C No connect 27 SPI Interface AD PWM SPI_MISO I GPIO27 No connect if not use 28 SPI Interface PWM SPI_CLK I O GPIO28 No connect if not use 29 SPI Interface AD SPI_CS I O GPIO29 No connect if not use 30 SPI Interface PWM SPI_MOSI O GPIO30 No connect if not use 31 3 3V Power DVDD Power 33 N C No connect 34 3 3 Power DVDD Power 35 N C No connect 36 N C No connect 37 N C N...

Page 13: ...rt Link application nLink Pin LED function 1 At wireless firmware and config upgrade mode this LED used to indicate configure and upgrade status 2 At Smart Link config mode this LED used to indicate APP to finish setting 3 At normal mode it s Wi Fi link status indicator High Flying strongly suggest customer fan out this pin to LED 1 2 2 Electrical Characteristics Absolute Maximum Ratings Parameter...

Page 14: ...igh Flying Electronics Technology Co Ltd www hi flying com 14 1 2 3 Mechanical Size HF LPB100 modules physical size Unit mm as follows Figure 3 HF LPB100 Mechanical Dimension HF LPB100 Module PCB symbol size mm as follows Figure 4 HF LPB100 PCB Symbol Size ...

Page 15: ...ement Region High Flying suggest HF LPB100 module better locate in following region at customer board which to reduce the effect to antenna and wireless signal and better consult High Flying technical people when you structure your module placement and PCB layout 1 2 5 External Antenna HF LPB100 module supports internal antenna and external antenna I PEX or SMA option for user dedicated applicatio...

Page 16: ...s User need download USB to UART port driver from High Flying web or contact with technical support people for more detail The external interface description for evaluation kit as follows Table 4 HF LPB100 Evaluation Kit Interface Description Function Name Description External Interface COM1 Main data command RS 232 interface RS485 Main data command RS 485 interface JTAG JTAG data debug interface ...

Page 17: ... Indicator nLink nLink WiFi LINK Indicator See 1 2 1 nReady nReady Module Bootup Ready Indicator On low Module bootup OK Off high Mouule botup failed Twinkle Remote Upgrade Ongoing Button nReset Used to reset the module nReload Restore factory default configuration after push this pin more than 4s See 1 2 1 WPS WPS Button 1 2 7 Order Information Base on customer detailed requirement HF LPB100 seri...

Page 18: ... to connect to LED indicate status when the module in wireless upgrade mode When module connects to AP AP associated this pin will output 0 This signal used to judge if module already at WiFi connection status Thers is pull up resister internal and no external pull up required If nLink function not required can leave this pin open nReady Module boot up ready signal Output Logics 0 effective The mo...

Page 19: ... hi flying com 19 User can de assert nReload signal 0 more than 4s through button or MCU pin then release module will restore to factory default configuration and re start boot up process If nReload function not required can leave this pin open UART0_TXD RXD UART port data transmit and receive signal ...

Page 20: ...e network nodes The wireless router we use at home or in office may be an AP STA short for Station each terminal connects to a wireless network such as laptops PDA and other networking devices can be called with a STA device 2 1 1 Basic Wireless Network Based On AP Infrastructure Infrastructure it s also called basic network It built by AP and many STAs which join in The characters of network of t...

Page 21: ...ransparent transmission mode The benefit of this mode is achieves a plug and play serial data port and reduces user complexity furthest In this mode user should only configure the necessary parameters After power on module can automatically connect to the default wireless network and server As in this mode the module s serial port always work in the transparent transmission mode so users only need...

Page 22: ... 50ms If the UART data interval is less than 300ms the data may be packaged into one fragment User can also set this interval to fast through AT command The UART data may be divided as fragment Through AT command AT UARTTE fast normal We recommend to use just normal parameter 2 3 2 UART Auto Frame HF LPB100 support UART auto frame function If user select open this function and setting auto frame t...

Page 23: ... for more detail 2 6 Firmware Update HF LPB100 module supports two on line upgrade methods Webpage Wi Fi Upgrade Remote Upgrade Webpage based Wi Fiupgrade please refer to 3 1 8 firmware upgrade page user can upload firmware file from PC to HF LPB100 HF LPB100 module also support upgrade from remote HTTP server keep module connects to AP router before excute remote HTTP upgrade Remote upgrade have ...

Page 24: ...ugh WiFi then read write GPIO PWM information through command data GPIO n OUT 0 Set GPIOn as output and output 0 Response GPIO OK or GPIO NOK GPIO n OUT 1 Set GPIOn as output and output 1 Response GPIO OK or GPIO NOK GPIO n GET Read GPIOn pin status Response ok 1 or GPIO NOK GPIO n SET Save GPIOn set Response GPIO OK or GPIO NOK PWM n frequency duty Set PWMn Channel output Response GPIO OK or GPIO...

Page 25: ...rmitted to connect to HF LPB100 module User can realize multi TCP link connection at each work mode Multi TCP link connection will work as following structure Upstream All dates from different TCP connection or client will be transmitted to the serial port as a sequence Downstream All data from serial port user will be replicate and broadcast to every TCP connection or client Detailed multi TCP li...

Page 26: ...dmin 3 1 1 Open Web Management Interface There is internal webpage and external webpage in modules The external webpage is for web management The internal webpage is only for upgrading Step 1 Connect laptop to SSID HF LPB100 of HF LPB100 module via wireless LAN card Step 2 After wireless connection OK Open Wen browser and access http 10 10 100 254 Step 3 Then input user name and password in the pa...

Page 27: ...Page HF LPB100 module can works at AP mode to simplify user s configuration can also works at STA to connect remote server through AP router Also it can configure at AP STA mode which provide very flexible application for customers Figure 15 Work Mode Page 3 1 4 STA Setting Page User can push Scan button to auto search Wi Fi AP router nearby and can connect with associate AP through some settings ...

Page 28: ...d network parameters Most of the system support DHCP to achieve IP address so we suggest to Enable DHCP server in most applications Figure 17 AP Setting Page 3 1 6 Other Setting Page HF LPB100 usually works at data transparent transmission mode At this mode the user device which connected with HF LPB100 will connect and communicate with remote PC or server At this page user need setting serial por...

Page 29: ...ectronics Technology Co Ltd www hi flying com 29 Figure 18 Other Setting Page 3 1 7 Account Management Page This page set web server s user name and password Figure 19 Account Page 3 1 8 Upgrade Software Page User can upgrade new software firmware version through Wi Fi ...

Page 30: ...ing and configuration can only effective after system restart User shall restart after finish all setting Figure 21 Restart Page 3 1 10 Restore Page After module restore factory default setting all user configuration profile will lose User can access http 10 10 100 254 to set again and user name and password is admin HF LPB100 will restore to AP mode for factory default setting ...

Page 31: ...iweb html It is for upgrading application and external webpage Please contact High Flying if need support on custimization for external webpage Figure 23 Internal Webpage 3 2 HF LPB100 Usage Introduction 3 2 1 Software Debug Tools High Flying use two common software tools debugging and applying HF LPB100 module User can also select other tools used to debug serial port Serial Debugging Software Co...

Page 32: ... Use HF LPB100 AP interface Debug PC2 connect to HF LPB100 through wireless connection another PC1 or user device connect to HF LPB100 module with serial port Figure 25 AP Interface Debug Connection 3 2 3 Default Parameter Setting Default SSID HF LPB100 Deault security mode open none User UART parameter setting 115200 8 1 None Default network parameter setting TCP Server 8899 10 10 100 254 Module ...

Page 33: ...ion If HF LPB100 configured as Server mode TCPUDPDbg Tools shall create Client mode connection Or otherwise create a Server mode connection Figure 27 TCPUDPDbg Tools Create Connection Then setting the TCP UDP connection parameters Default as following Figure 28 TCPUDPDbg Tools Setting Then click Create button to create a connection Figure 29 TCPUDPDbg Tools Connection ...

Page 34: ...port connects to user device So control agent Smart phone for this example can manage and control the user device through the wireless connection with HF LPB100 module 3 3 2 Remote Management Application Figure 31 Remote Management Application For this remote management application HF LPB100 works as STA mode and connects to Internet through wireless AP Module configured as TCP Client and communic...

Page 35: ...Transparent Serial Port Application For this transparent serial port application two HF LPB100 modules connect as below figures to build up a transparent serial port connection One HF LPB100 works as AP mode another HF LPB100 works as STA mode Make the STA device connects to AP Figure 32 Transparent Serial Port Application ...

Page 36: ...rt Parameters In configuration mode user can setting the module through AT instruction set which cover all web page setting function 4 1 1 Switch to Configuration Mode Two steps to finish switching from transparent transmission mode to configuration mode UART input after module receive and feedback a as confirmation UART input a after module receive a and feedback ok to go into AT instruction set ...

Page 37: ...ke the following sequence 4 2 AT Instruction Set Overview User can input AT Instruction through hyper terminal or other serial debug terminal also can program the AT Instruction to script User can also input AT H to list all AT Instruction and description to start Figure 35 AT H Instruction for Help 4 2 1 Instruction Syntax Format AT Instruction protocol is based on the instruction of ASCII comman...

Page 38: ...t change as you input Response Message RSP op para 1 para 2 para 3 para 4 CR LF CR LF Prefix of response message RSP Response string ok Success ERR Failure op para n Parameters if query command or Error code when error happened CR ASCII 0x0d LF ASCIII 0x0a Error Code Table 9 Error Code Describtion Error Code Description 1 Invalid Command Format 2 Invalid Command 3 Invalid Operation Symbol 4 Invali...

Page 39: ...work protocol parameters MAXSK Set Query TCP Client connection number TCPLK Query if TCP link already build up TCPTO Set Query TCP timeout TCPDIS Open Close TCP link SOCKB Set Query SOCKB parameters TCPDISB Open Close SOCKB TCP link TCPTOB Set Query SOCKB TCP timeout TCPLKB Query if SOCKB TCP link already build up SNDB Send data to SOCKB in Command Mode RCVB Receive data from SOCKB in Command Mode...

Page 40: ...time calibration function NTPTM Query time NTPSER Set Query NTP server IP Others Instruction Set WRMID Set module ID RLDEN Set Query GPIO45 status ASWD Set Query WiFi configuration code MDCH Set Wi Fi Auto Switch Function TXPWR Set Query Wi Fi Transmit Power SMTLK Start SmartLink function SMTLKVER Set Query SmartLink version WPS Start WPS function WPSTNEN Enable Disable GPIO 15 WPS function LPTIO ...

Page 41: ... When operate this command module switch from configuration mode to transparent transmission mode 4 2 2 4 AT TMODE Function Set Query module data transfer mode Setting is valid after reset Format Query Operation AT TMODE CR ok tmode CR LF CR LF Set Operation AT TMODE tmode CR ok CR LF CR LF Parameters tmode data transfer mode include throughput throughput mode cmd command mode pwm PWM GPIO mode 4 ...

Page 42: ...tion Format Query Operation AT LVER CR ok ver CR LF CR LF Parameters ver Module software detailed version information 4 2 2 8 AT FWSZ Function Query Wi Fi driver size Format Query Operation AT FWSZ CR ok size version CR LF CR LF Parametewrs size Wi Fi driver size Byte version Wi Fi driver version 4 2 2 9 AT RELD Function module restore to factory default setting Format Set Operation AT RELD CR ok ...

Page 43: ... User Parameters to Factory Default Parameters Format Query Operation AT CFGTF CR ok status CR LF CR LF Parameters status feedback operation status 4 2 2 14 AT UART Function Set Query serial port parameters Setting is valid after reset Format Query Operation AT UART CR ok baudrate data_bits stop_bit parity CR LF CR LF Set Operation AT UART baudrate data_bits stop_bit parity CR ok CR LF CR LF Param...

Page 44: ...ction enable Open auto frame function 4 2 2 16 AT UARTFT Function Set Query UART auto frame trigger time Format Query Operation AT UARTFT CR ok time CR LF CR LF Set Operation AT UARTFT time CR ok CR LF CR LF Parameters time Range 100 10000 Unit ms Auto frame trigger time 4 2 2 17 AT UARTFL Function Set Query UART auto frame trigger length Format Query Operation AT UARTFL CR ok len CR LF CR LF Set ...

Page 45: ... 1000 Byte The UART port will wait 3 seconds for input after this command is sent OK The data received from UART port is sent to SOCKA If the interval of two bytes is more than 10ms the data will be sent instantly 4 2 2 20 AT RECV Function Receive Data from SOCKA at Command Mode Format AT RECV data_lenth timeout CR ok data_lenth data_content CR LF CR LF Parameters data_lenth Lenth of receive data ...

Page 46: ... of the latest UDP packet received The data will be sent to the saved IP address and port If the module hasn t saved any IP address and port when power up The data will be sent to the IP address and port which is set by this command If set as UDP CLIENT the data will always be sent to the IP address and port set by this command 4 2 2 23 AT MAXSK Function Set Query TCP Client connection number Form...

Page 47: ...a If the time counter reaches the TCPTO the tcp channel will be break If the module work in TCP Client it will connect the TCP server instantly and when the module work in TCP Server the TCP client device should make the connection itself 4 2 2 26 AT TCPDIS Function Open Close TCP link Format Query Opera AT TCPDIS CR ok sta CR LF CR LF Set Operation AT TCPDIS on off CR ok CR LF CR LF Parameters Wh...

Page 48: ...ed any IP address and port when power up The data will be sent to the IP address and port which is set by this command If set as UDP CLIENT the data will always be sent to the IP address and port set by this command 4 2 2 28 AT TCPDISB Function Open Close SOCKB connection Format Query Operation AT TCPDISB CR ok sta CR LF CR LF Set Operation AT TCPDISB on off CR ok CR LF CR LF Parameters When setti...

Page 49: ...to SOCKB at Command Mode Format AT SNDB data_lenth CR ok CR LF CR LF Parameters data_lenth Lenth of send data Range 0 1000 Byte The UART port will wait 3 seconds for input after this command is sent OK The data received from UART port is sent to SOCKB If the interval of two bytes is more than 10ms the data will be sent instantly 4 2 2 32 AT RCVB Function Receive datas from SOCKB at Command Mode Fo...

Page 50: ...e WEP H When auth OPEN or SHARED effective in HEX format WEP A When auth OPEN or SHARED effective in ASCII format TKIP When auth WPAPSK or WPA2PSK effective AES When auth WPAPSK WPA2PSK effective key password When encry is WEP H password is in HEX format password length is 10 or 26 When encry is WEP A password is in ASCII format password length is 5 or 13 When encry is TKIP or AES password is in A...

Page 51: ...address CR ok CR LF CR LF Parameters code security code 8888 default value Mac_address STA MAC address such as ACCF23FF1234 4 2 2 37 AT WSLK Function Query STA WiFi link status Format Query Operation AT WSLK CR ok ret CR LF CR LF Parameters ret Disconnected if no WiFi connection AP SSID AP s MAC if WiFi connection available 4 2 2 38 AT WSLQ Function Query STA WiFi signal strength Format Query Oper...

Page 52: ...ht away 4 2 2 41 AT LANN Function Set Query AP s network parameters Setting is valid after reset Format Query Operation AT LANN CR ok ipaddress mask CR LF CR LF Set Operation AT LANN ipaddress mask CR ok CR LF CR LF Parameters ipaddress AP s IP address mask AP s net mask 4 2 2 42 AT WAP Function Set Query AP Wi Fi parameters Setting is valid after reset Format Query Operation AT WAP CR ok wifi_mod...

Page 53: ...AES When auth WPA2PSK available key security code ASCII code smaller than 64bit and bigger than 8 bit 4 2 2 44 AT WAMAC Function Query AP MAC address parameters Format Query Operation AT WAMAC CR ok mac_address CR LF CR LF Parameters mac_address AP s MAC address Note Module AP mode s MAC address is related to STA mode s MAC address If user need changeto others please contact with high flying techn...

Page 54: ...MAC address of STA device connecting to module AP Format Query Operation AT WALK CR ok status CR LF CR LF Parameters status MAC address of STA device connecting to module AP No Connection No STA device connecting to module AP 4 2 2 48 AT WALKIND Function Enable Disable indication of module AP connection status Format Query Operation AT WALKIND CR ok status CR LF CR LF Set Operation AT WALKIND stat...

Page 55: ...l filename CR ok CR LF CR LF Parameters url the upgrade file url address the last charter shall be within 20 characters filename the upgrade file name it s optional and not saved parameter If provide this file name here the module will start upgrade right away 4 2 2 51 AT UPFILE Function Set Query remote upgrade configure file name Format Query Operation AT UPFILE CR ok filename CR LF CR LF Set Op...

Page 56: ...LF Parameters port The remote upgrade UDP port of log file 4 2 2 54 AT UPST Function Start remote upgrade Format Query Operation AT UPST CR ok log CR LF CR LF Parameters log feedback the status of remote upgrade Note After execute this command the HF LPB100 will automatic start upgrade base on the setting of UPURL UPFILE command contents 4 2 2 55 AT WEBU Function Set Query webpage user name and pa...

Page 57: ...ime calibration interval Format Query Operation AT NTPRF CR ok num CR LF CR LF Set Operation AT NTPRF num CR ok CR LF CR LF Parameters num time calibration inverval range 0 720 default 30 minutes 10 minutes for each step set 0 means no time calibration automatically 4 2 2 58 AT NTPEN Function Enable Disable time calibration function Setting is valid after reset Format Query Operation AT NTPEN CR o...

Page 58: ...ipaddress CR LF CR LF Set Operation AT NTPSER ipaddress CR ok CR LF CR LF Parameters ipaddress NTP network server IP address 61 164 36 105 default value 4 2 2 61 AT WRMID Function Set module ID Format Set Operation AT WRMID wrmid CR LF CR LF Parameters wrmid set module s ID within 20 characters 4 2 2 62 AT RLDEN Function Set Query nReload Pin function status Format Query Operation AT RLDEN CR ok s...

Page 59: ...t will switch to AP mode itself in one minute auto Enable Wi Fi auto detect function The module will reset itself when encounter any abnormal The default time interval is 10 minutes default mode 3 120 unit minute Set the time interval to reset itself when abnormal 4 2 2 65 AT TXPWR Function Set Query Wi Fi Transmit Power Real Transmit Power Default Transmit Power 16dBm Setting Value 0 5dBm Setting...

Page 60: ...sion sniffer mode SMTLK 4 0 SmartLink V4 version sonic mode ver 3 Use SmartLink V3 version sniffer mode 4 SmartLink V4 version sonic mode The corresponding APP can be downloaded from our website See appendix D for details 4 2 2 68 AT WPS Function Start WPS function Format Query Operation AT WPS CR ok status CR LF CR LF Parameters status WPS status The module will reboot and work in STA mode connec...

Page 61: ...R ok status CR LF CR LF Set Operation AT LPTIO status CR ok CR LF CR LF Parameters status nReady nLink WPS function mapping off lpb100 nReady nLink WPS function are mapping to HF LPB100 corresponding pin Pin44 Pin43 Pin15 on lpt100 nReady nLink WPS function are mapping to HF LPT100 corresponding pin Pin9 Pin10 Pin8 lpt200 nReady nLink WPS function are mapping to HF LPT200 corresponding pin Pin11 P...

Page 62: ...tus change command AT WMODE and so on need to reboot before valid But may use this command only to reboot the Wi Fi Chip to make the corresponding command valid This is AT WIFI DOWN and then AT WIFI UP 4 2 2 72 AT SMEM Function Query the RAM status Format Query Operation AT SMEM CR ok status CR LF CR LF Parameters status The RAM status ...

Page 63: ...baked with window time 168 hours 3 Recommend to oven bake with N2 supplied 4 Recommend end to reflow oven with N2 supplied 5 Baked required with 24 hours at 125 5 before rework process 6 Recommend to store at 10 RH with vacuum packing 7 If SMT process needs twice reflow 1 Top side SMT and reflow 2 Bottom side SMT and reflow Case 1 Wifi module mounted on top side Need to bake when bottom side proce...

Page 64: ...Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 64 5 3 Shipping Information TAPE BOX Size 340 340 70 mm Size 340 340 350 mm inside Figure 37 Shipping Information Note 1 tape 500pcs 1 box 5 tapes 5 500 pcs 2500pcs ...

Page 65: ... High Flying Electronics Technology Co Ltd www hi flying com 65 APPENDIX A HW REFERENCE DESIGN Detailed HF LPB100 Evluation Board design source files pls access High Flying web download page or contact with High Flying technical support people to acquire ...

Page 66: ... the module is reset B 1 Network Command B 1 1 GPIO channel OUT value Function Set GPIO Channel value temporarily Parameters channel GPIO Channel number it can be 11 12 15 18 20 23 GPIO Pin number value GPIO Channel value 1 high voltage 0 low voltage Return Data GPIO OK Command successful GPIO NOK Command failed B 1 2 GPIO channel GET Function Query GPIO Channel value Parameters channel GPIO Chann...

Page 67: ...er it can be 11 12 15 18 20 23 GPIO Pin number Return Data GPIO OK Command successful GPIO NOK Command failed B 1 4 PWM channel frequency duty Function Set PWM Channel output temporarily Parameters channel PWM Channel number it can be 11 12 18 20 GPIO Pin number frequency PWM Channel frequency it can be 500 60000 duty PWM Channel duty it can be 0 100 Return Data PWM OK Command successful PWM NOK C...

Page 68: ... Co Ltd www hi flying com 68 B 1 5 PWM channel GET Function Query PWM Channel output Parameters channel PWM Channel number it can be 11 12 18 20 GPIO Pin number Return Data ok frequency duty frequency PWM Channel frequency duty PWM Channel duty PWM NOK Command failed B 1 6 PWM channel SET ...

Page 69: ...cessful PWM NOK Command failed B 2 Hexadecimal Network Command Send hexadecimal data to fastly read module s port status B 2 1 Read all GPIO Channel Send Data 0a Return Data 8a value value bit0 bit1 represent GPIO15 GPIO23 value B 2 2 Reverse GPIO Channel value Send Data 03 channel channel GPIO Channel number it can be 01 02 GPIO15 GPIO23 Return Data 83 channel value channel GPIO Channel number it...

Page 70: ...l 2 GPIO18 frequency value6 Low byte of PWM Channel 2 GPIO18 frequency value7 High byte of PWM Channel 3 GPIO20 frequency value8 Low byte of PWM Channel 3 GPIO20 frequency B 2 4 Write PWM Channel Frequency Send Data 32 channel value1 value2 channel PWM Channel number value1 High byte of PWM Channel frequency value2 Low byte of PWM Channel frequency Return Data b2 channel value1 value2 Channel PWM ...

Page 71: ...nel Duty Send Data 22 channel value1 channel PWM Channel number value1 Duty of PWM Channel Return Data a2 channel value1 Channel PWM Channel number value1 Duty of PWM Channel B 2 7 Save Present GPIO PWM Setting Send Data 7a Return Data fa B 2 8 Assert All GPIO Channel Low Send Data 04 Return Data 84 00 B 2 9 Assert All GPIO Channel High Send Data 05 Return Data 85 01 B 2 10 Read Resources of modul...

Page 72: ...ver IP address and Port Number Format Query Operation AT HTTPURL CR ok IP Port CR LF CR LF Set Operation AT HTTPURL IP Port CR ok CR LF CR LF Parameters IP IP address Port Port number C 1 2 AT HTTPTP Function Set Query HTTP request type Format Query Operation AT HTTPTP CR ok Type CR LF CR LF Set Operation AT HTTPTP Type CR ok CR LF CR LF Parameters Type GET default or POST C 1 3 AT HTTPPH Function...

Page 73: ...l header Format Query Operation AT HTTPUA CR ok Parameter CR LF CR LF Set Operation AT HTTPUA Parameter CR ok CR LF CR LF Parameters Parameter Max length is 20 bytes C 1 6 AT HTTPDT Function Send HTTP request or data Format Set Operation AT HTTPDT Data CR ok CR LF CR LF Parameters Data HTTP request data send AT HTTPDT directly if no data to be sent C 2 HTTP Example HTTP parameter settings are as f...

Page 74: ...t will be sent as the following instance POST abcd HTTP 1 1 Connection keep alive User Agent lwip1 3 2 Content Length 4 Host 192 168 0 127 8999 abcd The data received from HTTP server will be output to serial port and end with ok If the module hasn t received data from HTTP server for 5 second it will cut the TCP link with HTTP server C 3 Sending HTTP Raw Data in Throughput Mode Recommend Step 1 C...

Page 75: ...B100 Low Power Wi Fi Module User Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 75 C 4 Sending HTTP Request By AT Command Step 1 Configure HTTP AT command SOCKB must set as None ...

Page 76: ...HF LPB100 Low Power Wi Fi Module User Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 76 Step 2 Configure module connecting to router AP and reboot Step 3 Send HTTP request ...

Page 77: ...stats comp FrontDownloads_list01 dc html Android Platform http www hi flying com download_detail_dc downloadsId 9a0d0290 477e 4184 8636 18510eaed6b1 comp_stats comp FrontDownloads_list01 dc html D 2 1 SmartLink APP V4 Config Tool For LPB100U only Android IOS Platform http www hi flying com download_detail_dc downloadsId 7b35fdc4 b649 4e23 87b9 a3324ae76b43 html D 3 EVK Quick Start Guide Download A...

Page 78: ...NFORMATION Address Room 1002 Building 1 No 3000 Longdong Avenue Pudong New Area Shanghai China 201203 Web www hi flying com Service Online 400 189 3108 18616078755 Sales Contact sales hi flying com For more information about High Flying modules applications and solutions please visit our web site http www hi flying com en END OF DOCUMENT ...

Page 79: ...dance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fo...

Page 80: ...sting their end product for any additional compliance requirements required with this module installed Validity of using the module certification In the event that these conditions cannot be met for example certain laptop configurations or co location with another transmitter then the FCC authorization for this module in combination with the host equipment is no longer considered valid and the FCC...

Page 81: ...authorized persons without the written consent of High Flying The recipient of this document shall respect the security status of the information The master of this document is stored on an electronic database and is write protected and may be altered only by authorized persons at High Flying Viewing of the master document electronically on electronic database ensures access to the current issue A...

Reviews: