Unit installation and connections shall only be performed by qualified licensed staff. The
electrical connections must be carried out by a person who has proper professional training and experience in the
relevant accident prevention regulations, as well as other generally recognized safety and occupational health codes,
perform unit jobs.
2.0 Assembly
The central ventilation units EVO-R must be mounted in a vertical position. Ensure that there is a waste water connection for
cooler module (optional) in the installation area. Assembly should take place in such a way to enable preferably short ventilation
ducts and their trouble-free connection to the unit. Tight bends can lead to increased pressure loss and flow noise. The unit can
be turned 180° for optimal installation, so that the outdoor/exhaust air and extract/supply air inlets and outlets can be on the left
or right side. There is no need for bends and long stretches of pipeline due to these features. They reduce losses and increase
the degree of efficiency of the system.
Important notes:
- The ventilation ducts must not become kinked.
- The connections to the connection valves must be firm and tight.
- Flange connections must be leakproof and firm
- If necessary, vibration isolators can be used between unit and floor.
- Make sure that sufficient duct length is available before connecting the bend etc. to the device.
To prevent contact with moving parts the outdoor spigot should be placed on the exhaust air
side in case of no duct connection. (Chapter 7.9)
Make sure that the device is placed on a flat surface before any assembly work.
Assembly area
Observe the following criteria during installation to ensure that the device service is comfortable. (Fig. 5)
A is the minimum distance for servicing the terminal box.
B is the minimum distance for opening service cover.
MODEL
A (mm)
B (mm)
C (mm)
D (mm)
EVO-15R
600
910
1110
1145
EVO-20R
600
1010
1210
1245
EVO-30R
600
1120
1320
1355
EVO-50R
600
1390
1590
1625
EVO-60R
600
1510
1710
1745
EVO-80R
600
1760
1960
1995
EVO-95R
600
1860
2060
2095
EVO-120R
600
2010
2210
2245
EVO-150R
600
2260
2460
2495
Fig. 5
Summary of Contents for EVO-R
Page 1: ...EVO R COMPACT AIR HANDLING UNIT WITH ROTARY HEAT RECOVERY ...
Page 129: ...129 Fig 170 Fig 171 ...
Page 130: ...130 Fig 171 ...
Page 132: ...132 Fig 173 Fig 174 ...
Page 133: ...133 Fig 174 ...
Page 135: ...135 Fig 176 Fig 177 ...
Page 136: ...136 Fig 177 ...
Page 138: ...138 Fig 179 Fig 180 ...
Page 139: ...139 Fig 180 ...
Page 141: ...141 Fig 182 Fig 183 ...
Page 142: ...142 Fig 183 ...
Page 144: ...144 Fig 185 Fig 186 ...
Page 145: ...145 Fig 186 ...
Page 147: ...147 Fig 188 Fig 189 ...
Page 148: ...148 Fig 189 ...
Page 150: ...150 Fig 191 Fig 192 ...
Page 151: ...151 Fig 192 ...
Page 153: ...153 Fig 194 Fig 195 ...
Page 154: ...154 Fig 195 ...
Page 155: ...155 ...