![AERMEC RePuro 100 Technical Manual Download Page 19](http://html.mh-extra.com/html/aermec/repuro-100/repuro-100_technical-manual_3049195019.webp)
19
IREPPY - 1404 - 4238051_01
RePuro
100
170
250
250R
350
350R
450
450R
550
550R
650
650R
Nominal air flow
m
3
/h
100
170
250
350
450
550
650
Available static pressure
Pa
85
20
195
133
100
120
70
Winter recovery efficiency
%
94,4
91,2
91,9
89,4
90,3
88,6
87
Recovered heating capacity
W
957
1573
2329
3171
4118
4940
5734
Winter recovery efficiency (*)
%
90,6
85,3
86,3
82,2
83,7
81
78,4
Recovered heating capacity (*)
W
601
963
1433
1910
2500
2957
3386
Summer recovery efficiency
%
90,6
85,3
86,4
82,2
83,7
81
78,5
Recovered cooling capacity
W
180
289
430
573
750
887
1015
Air flow (2)
m
3
/h
75
125
150
200
300
350
450
Available static pressure
Pa
135
110
331
376
210
300
270
Winter recovery efficiency
%
95,7
93,2
94,8
93,3
93
92,1
90,3
Recovered heating capacity
W
728
1181
1441
1891
2830
3267
4118
Winter recovery efficiency (*)
%
92,7
88,6
91,1
88,6
88,2
86,6
83,7
Recovered heating capacity (*)
W
462
735
908
1177
1758
2014
2500
Summer recovery efficiency
%
92,7
88,6
91,2
88,7
88,3
86,7
83,7
Recovered cooling capacity
W
138
220
272
353
527
604
750
Air flow (1)
m
3
/h
50
75
75
100
150
175
200
Available static pressure
Pa
185
210
426
526
310
430
485
Winter recovery efficiency
%
97
95,7
97,2
96,4
96,2
95,7
95,1
Recovered heating capacity
W
492
728
739
977
1463
1697
1928
Winter recovery efficiency (*)
%
95
92,7
95,3
93,9
93,6
92,7
91,7
Recovered heating capacity (*)
W
315
462
475
623
932
1077
1218
Summer recovery efficiency
%
95
92,7
95,3
93,9
93,6
92,7
91,7
Recovered cooling capacity
W
95
138
142
187
280
323
365
Weight
kg
25
25
48
48
55
55
55
Maximum power input
W
45
65
160
180
220
280
360
Pre-heater element power input (ver-
sions
R
)
W
500
500
500
500
500
500
500
Power supply
V ~ Hz
230 ~ 50
* Winter recovery
condition
EN 308
Extract air
25°C D.B.
27% R.H.
Supply air
5°C D.B.
50% R.H.
Winter recovery
condition
Extract air
20°C D.B.
50% R.H.
Supply air
-10°C D.B.
80% R.H.
The available pressure may change
from the nominal due to the anti-freeze
control
Summer recovery
condition
Extract air
26°C D.B.
50% R.H.
Supply air
32°C D.B.
50% R.H.
(1) (2) Performances refer to conditions different to the nominal conditions
Model
Minimum external temp.
Maximum external temp.
RePuro100 - RePuro170
RePuro250 - RePuro350
RePuro450 - RePuro550 - RePuro650
-10°C
+50°C
RePuro250R - RePuro350R
RePuro450R - RePuro550R - RePuro650R
-15°C
+50°C
8.
TECHNICAL DATA
9.
OPERATING LIMITS
Summary of Contents for RePuro 100