background image

5

 

 

Bevilacqua (VR)

 

 

                  

Commercial Director  

 

 

Luigi Zucchi 

 

 

 

 

 

 

AERMEC S.p.A. 

37040 Bevilacqua (VR) Italy – Via Roma, 996 

Tel. (+39) 0442 633111 – Fax (+39) 0442 93577 

Partita Iva: 00234050235 

www.aermec.com 

 

 

DICHIARAZIONE DI CONFORMITÀ CE / EC DECLARATION OF CONFORMITY / DECLARATION DE CONFORMITE CE  

KONFORMITÄTSERKLÄRUNG EG / DECLARACIÓN DE CONFORMIDAD CE 

 

NAME 

 

MODEL* ______________ 

 

 

SERIAL NUMBER________ 

 

 

DATE_________________ 

 

 

 

Noi, firmatari della presente, dichiariamo sotto la nostra esclusiva responsabilità che l'insieme in oggetto così definito: 

We, the undersigned, hereby declare under our own responsibility that the assembly in question, defined as follows: 

Nous, Signataires du présent acte, déclarons sous notre responsabilité exclusive que le groupe cité à l’objet défini de la façon suivante: 

Die Unterzeichner erklären unter eigener Verantwortung, dass die oben genannte Maschineneinheit, bestehend aus: 

Nosotros, los abajo firmantes, declaramos bajo nuestra exclusiva responsabilidad, que el conjunto en cuestión, denominado: 

 

Nome / Name / Nom / Name / Nombre   

NOME DI PROVA 

Tipo / Type / Type / Typ / Tipo   

 

TIPOLOGIA DI UNITÀ 

Modello / Model / Modèle / Model / Modelo 

MODELLO (PER ESTESO) 

 

A cui questa dichiarazione si riferisce è conforme a tutte le disposizioni pertinenti delle seguenti direttive: 

To which this declaration refers, complies with all the provisions related to the following directives: 

Auquel cette déclaration se réfère, est conforme à toutes les dispositions relatives des directives suivantes: 

Das Gerät, auf welches sich diese Erklärung bezieht, entspricht allen Verordnungen im Zusammenhang mit den folgenden Richtlinien: 

A la que esta declaración se refiere, es conforme con todas las disposiciones pertinentes de las siguientes directivas: 

 

Direttiva Macchine: 2006/42/CE 

Direttiva Compatibilità Elettromagnetica EMCD: 2014/30/UE 

Direttiva PED in materia di attrezzature a pressione: 2014/68/UE 

Direttiva RoHS sulla restrizione dell’uso di determinate sostanze pericolose nelle AEE: 2011/65/UE 

Direttiva ErP per la progettazione ecocompatibile: 2009/125/CE 

 

L’oggetto della dichiarazione di cui sopra è conforme alle pertinenti normative di armonizzazione dell’Unione: 

The above-mentioned declaration complies with the harmonised European standards: 

L'objet de la déclaration reportée ci-dessus est conforme aux normes d’harmonisation relatives de l'Union: 

Der Gegenstand der genannten Erklärung entspricht den diesbezüglichen harmonisierten Normen der europäischen Gemeinschaft: 

El objeto de la declaración de arriba es conforme con las normativas pertinentes de armonización de la Unión: 

 

CEI EN 60204-1: 2018  

 

 

CEI EN IEC 61000-6-1: 2019 

 

UNI EN 378-2: 2017 

UNI EN ISO 12100: 2010    

 

CEI EN 61000-6-3: 2007 + A1: 2013 

UNI EN 12735-1: 2020 

 

* NOTA: La presente dichiarazione non è valida per tutte le macchine non conformi al regolamento 2016/2281 ed elencate nella Tabella 1 sotto riportata. 

* NOTE: This declaration is not valid for machines not compliant with regulation 2016/2281 and listed in Table 1 below. 

* REMARQUE:

 

Cette déclaration n'est pas valable pour les machines non conformes au règlement 2016/2281 et listées dans le tableau 1 ci-dessous. 

* ANMERKUNG: Diese Erklärung gilt nicht für Maschinen, die nicht der Verordnung 2016/2281 entsprechen und in der nachstehenden Tabelle 1 aufgeführt sind. 

* NOTA: Esta declaración no es válida para máquinas que no cumplen con la regulación 2016/2281 y se enumeran en la Tabla 1 a continuación. 

 

 

La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva del fabbricante.  

La persona autorizzata a costituire il fascicolo tecnico è Luca Martin, Via Roma 996, 37040 Bevilacqua (VR) Italy.  

L'unità è conforme ai dati di progetto riportati nel fascicolo tecnico al paragrafo Definizione dell'Insieme, è in accordo con la direttiva 2014/68/UE e soddisfa la 

procedura di Garanzia Totale di qualità (modulo H) con certificato n. 06/270-QT3664 Rev.14 emesso dall’organismo notificato n. 1131 CEC via Pisacane 46 

Legnano (MI) - Italia. 

L'elenco dei componenti critici pertinenti al numero di fabbrica sopra riferito, secondo quanto previsto dalla Direttiva 2014/68/UE, è fornito a corredo della 

presente Dichiarazione di Conformità (doc. "Lista componenti per Dichiarazione di Conformità"). 

Dichiariamo inoltre che, al momento dell'immissione sul mercato Europeo di tale apparecchiatura precaricata da parte di Aermec S.p.A (che importa o produce 

nell'Unione), gli idrofluorocarburi, in essa contenuti, sono considerati nel sistema di quote dell'Unione di cui al Capo IV del regolamento UE 517/2014 in quanto 

sono stati immessi sul mercato da un produttore o importatore di idrofluorocarburi cui si applica l'articolo 15 del regolamento UE 517/2014. 

 

 

 

DECLARATION OF CONFORMITY

NRV

NRV

Outdoor chiller

0550

Summary of Contents for NRV 0550

Page 1: ...EN Technical Manual TRANSLATION FROM ORIGINAL 5523421_02 22 02 OUTDOOR CHILLER MICROCHANNEL COILS EASY AND QUICK TO INSTALL COMPACT MODULE RELIABILITY AND MODULARITY NRV 0550...

Page 2: ......

Page 3: ...ce and in depth engineering research and it is manufactured using top quality materials and cutting edge technologies In addition the CE mark guarantees that our appliances fully comply with the requi...

Page 4: ...15 BASIC PRINCIPLES ON MICROCHANNEL COIL CORROSION 16 CLEANING MICRO CHANNEL COIL 16 OPERATING RANGE 17 PERFORMANCE SPECIFICATIONS 18 GENERAL SPECIFICATIONS 18 ELECTRICAL DATA 19 DIMENSIONS AND WEIGHT...

Page 5: ...e ci dessus est conforme aux normes d harmonisation relatives de l Union Der Gegenstand der genannten Erkl rung entspricht den diesbez glichen harmonisierten Normen der europ ischen Gemeinschaft El o...

Page 6: ...200 L WSH 1202 WSH 1402 WSH 1602 WSH 1802 WSH 2002 WSH 2202 WSH 2502 WSH 2802 NRG 0802 L NRG 0804 L Bevilacqua VR Commercial Director Luigi Zucchi This declaration of conformity has been released und...

Page 7: ...low heat load conditions EXTENDED OPERATING RANGE This range can work at full load with outdoor temperature up to 50 C This occurs in the high efficiency versions and also for example in versions wit...

Page 8: ...t recovery Without heat recovery D With desuperheater 11 Version A High efficiency E Silenced high efficiency 12 Coils Aluminium micro channel O Painted aluminium microchannel R Copper Copper S Copper...

Page 9: ...refrigerant gas to the evaporator recovery and the coil Liquid indicator It is used to verify that the expansion system is powered correctly and the presence of humidity in the cooling circuit STANDA...

Page 10: ...e always a prompt diagnosis of the unit operation Creation of operation time periods required for efficient programming A self adaptive logic is used to defrost This logic allows you to adjust the num...

Page 11: ...c circuit system side System side heat exchanger plate heat exchanger Heat exchanger electric resistance Water filter Flow Switch Differential pressure switch Safety valve Manual air vent valve Automa...

Page 12: ...12 PRINCIPLE FUNCTIONING DIAGRAMS NRV0550 with mechanical thermostatic valve Schema frigorifero NYB Evaporator Condenser Condenser Evaporator...

Page 13: ...high pressure switch finned heat exchanger scroll compressor drier filter insulated pipe regulation line Pressure connection high pressure side temperature probe high pressure transducer low pressure...

Page 14: ...fold KREC Accessory kit to remote the electric power supply input to the back RIF Power factor correction Connected in parallel to the motor allowing about 10 reduction of input current COMPATIBILITY...

Page 15: ...te corrosion Within the manufacturing plants corrosive gas may result from the proces sing of chemicals or by the typical industrial processes used in manufactu ring Potential sources of risk to be co...

Page 16: ...oisture in the air is one such electrolyte Humid air contaminated with corrosive gasses further accelera tes the corrosion rate as the air s current carrying otential increases Temperature Chemical re...

Page 17: ...mend you first contact our technical sales service Note If the unit is installed in particularly windy areas you must provide a windbreak to prevent unit malfunctions It should be installed if wind sp...

Page 18: ...at exchanger Type plates Number no 1 Resistance no W Connections with Grooved Joints Diameter A in out 6 E in out 6 Desuperheater Heat Exchanger Type plates Number no 1 Resistance no W Connection type...

Page 19: ...GHTS Size Notes ver 0550 Electrical data Standard unit Height A mm 2480 E mm 2480 Width A mm 2200 E mm 2200 Length A mm 1190 E mm 1190 Vacuum weight A kg 1105 E kg 1105 Size Notes ver 0550 Electrical...

Page 20: ...24 61 48 38 80 63 51 0550E TA d b 10 25 35 46 10 25 35 46 10 25 35 46 10 25 35 46 TW out 4 7 10 15 Glycol 10 0 00 0 00 0 00 Pc 118 5 104 0 93 1 84 7 131 6 115 5 103 5 93 5 144 0 126 3 113 5 165 6 145...

Page 21: ...nsitive to the phenomenon of extra oxygenation of the water an event that can be encouraged by the incorrect positioning of some components This phenomenon can trigger corrosion processes and subseque...

Page 22: ...0 955 0 947 0 939 0 932 0 924 Pe 1 0 996 0 994 0 992 0 99 0 988 0 986 0 984 0 982 0 98 Dp 1 1 082 1 102 1 143 1 201 1 271 1 351 1 435 1 52 1 602 CORRECTIVE FACTORS GLYCOL Qwc Water flow rate correctiv...

Page 23: ...e at the moment of installation 1200 Xg Yg 1 3 2 4 Top View WEIGHT WITHOUT PACKING Module 1 Model Version Module kit Weight kg Barycentre mm Distribution of weights on the supports NRV 0550 00 no Hydr...

Page 24: ...C S p A Via Roma 996 37040 Bevilacqua VR Italia Tel 39 0442 633111 Fax 39 0442 93577 marketing aermec com www aermec com Aermec reserves the right to make all modification deemed necessary for improvi...