OTHER INFORMATION
FAN SPEED
●
By setting the fan to AUTOMATIC during operation in
COOLING or HEATING mode, the microprocessor reduces
the fan speed when the ambient temperature approaches
the value set.
When the room reaches the temperature set, the compressor
stops and the fan on the indoor unit continues operating at
the ultra-low speed setting.
In HEATING MODE, the fan on the indoor unit can stop.
●
On dehumidication mode the microprocessor controls the
fan speed which cannot be modified manually.
VENTILATION MODE
●
If the room temperature is higher the the set value (read on
the display of the remote control) the fan keeps on running.
●
If the room temperature is lower than the set value the fan
stops (if it is still it remains still).
●
The fan speed can be changed manually.
However, when the unit is started the fan runs always at
minimum speed.
OPERATION LIMITS
The air conditioner is equipped with control devices which prevent
the unit to work under dangerous conditions.
Under certain conditions, these devices may cut in and stop
the air conditioner:
If the air conditioner works continuously on cooling mode inside
a room with high relative humidity (higher than 80%) there
might be the production of condensate by air delivery of the
indoor unit.
The condensate might collect on the object underneath or on
the floor
BLACK OUT
The air conditioner stops.
After the black out, the air conditioner must be switiched on
again (ON / OFF button).
DELAIED START OF COMPRESSOR
Each time the compressor stops, 3 minutes at least must elapse
before a new starting.
The same result is achieved by pressing the MODE key repeatedly
when the conditioner is running.
This time avoids overloads to the compressor and cannot be
modified.