WARNING check that the power
supply is disconnected before carrying
out any procedures on the unit.
WARNING:
before carrying out any
operation, use appropriate personal
protective equipment.
WARNING: the device must be
installed in compliance with the
national plant engineering rules.
WARNING: electrical wirings,
installation of the fan coils and relevant
accessories should be performed by
a technician who has the necessary
technical and professional expertise
to install, modify, extend and maintain
systems, and who is able to check the
systems for the purposes of safety and
correct operation.
WARNING: Install a device, main
switch, or electric plug so you can fully
disconnect the device from the power
supply.
WA R N I N G : C o n s u l t a l l
documentation before starting the
installation.
The essential indications to install the
device correctly are given here.
The completion of all the operations
in accordance with the specific
requirements is however left to the
experience of the installation engineer.
The water, condensate discharge and
electrical circuit ducts must be provided for.
The fan coil must be installed in such a
position that the air can be distributed
throughout the room and so that there
are no obstacles (curtains or objects) to
the passage of the air from the suction
louvers.
The fan coil should be installed in such
a way as to facilitate routine (filter
cleaning) and special maintenance
operations, as well as access to the air
drain valve on the side of the unit frame
(connections side).
Do not install units in rooms where
there are inflammable gases or acid
or alkaline substances that could
irretrievably damage the aluminium-
copper heat exchanger or the internal
plastic parts.
Do not install the unit in workshops or
kitchens where the oil vapours mixed
with the treated air can be deposited
on the exchange coils, reducing their
performance, or on the parts inside the
unit, damaging the plastic parts.
Choose a position at the centre of the
room whenever possible; adjusting the
air output allows air to be distributed
optimally within the room. Generally
the best position of the fins is that
which allows the launch of the air
adhering to the ceiling for the coined
effect, during cold functioning. The
opening positions are indicated on
the side section of the air flow unit for
correct machine operation when hot
(20° opening) and cold (10° opening).
There are intermediate and completely
closed positions available. Thanks to the
special shapes of the fins, the machine
can also function with the deflectors
completely closed.
The regulation of the air output allows
the air to be distributed optimally in
the room.
Do not install at a height above three
metres.
The FCLI unit is prepared for connections
with channelling for the fresh air and for
the delivery of treated air to an adjacent
room.
WARNING:
After completing the
installation check the operation of the
condensate discharge system, the seal of
the hydraulic fittings, insulation of ducts
and pipes. Then perform a functional test.
In the event of malfunction consult the
Alarm Codes Table to interpret the alarms
indicated by the
2 LEDs (Alarm / Power)
that relay the operating status of the unit.
The box with Inverter card is positioned
outside the unit.
DANGER!
Only qualified service
personnel can access it.
INSTALLATION INFORMATION
RECOMMENDED INSTALLATION TEMPLATE
Max. dimensions of water connections
Max. dimensions of installation bracket
Max. dimensions of installation bracket
Module "600"
Module "840"
Max. dimensions of
installation bracket
Max. dimensions of
installation bracket
Max. dimensions of
installation bracket
Max. dimensions of
installation bracket
Condensate drain
side
Max. dimensions of
water connections